跳到主要导航 跳到搜索 跳到主要内容

Microscale bone interlocking enhances osseointegration strength on the rough surface of 3D-printed titanium implants: experimental and finite element analysis

  • Tianyu Shu
  • , Haoyu Shi
  • , Meng Li
  • , Yu Chia Lin
  • , Ang Li
  • , Dandan Pei
  • Xi'an Jiaotong University

科研成果: 期刊稿件文章同行评审

6 引用 (Scopus)

摘要

Background: The advent of 3D-printing technology, which is capable of on-demand fabrication, has ushered in a new era for fixed implant prosthodontics. Over the past decade, immediately loaded 3D-printed titanium implants have demonstrated predictable clinical outcomes in human jaws, highlighting their superior osseointegration strength, which is attributed to their increased surface roughness. However, the biomechanical mechanisms underlying this enhanced osseointegration strength remain elusive, thereby impeding the standardization and broader clinical application of 3D-printed titanium implants. Methods: Experimental 3D-printed titanium implants were fabricated via selective laser melting (SLM), and conventional sandblasted and acid-etched titanium implants (CNC-SLA) served as the control group. Implant surfaces were characterized with scanning electron microscopy, surface profilometry, energy-dispersive X-ray spectroscopy, and a contact angle meter. Implants (n = 10) were surgically inserted into the femoral condyle of New Zealand rabbits. At weeks 1, 2, and 8, micro-CT and undecalcified histological sections were used to assess histological osseointegration (n = 6), whereas removal torque analysis was performed to evaluate osseointegration strength (n = 4). At week 8, microscale finite element analysis of different bone-implant interfaces was conducted to predict the peri-implant bone strain under multidirectional implant loading. Results: The surface roughness of the SLM implants was significantly greater than that of the CNC-SLA implants. Histological osseointegration assessments revealed equal levels of SLM and CNC-SLA implants at weeks 1, 2, and 8. Notably, after week 2, bone interlocking phenomenon appeared on the SLM implants. The removal torque for the SLM implants at week 2 were significantly greater (P < 0.05) than that for the CNC-SLA implants at the same time point and was comparable to the CNC-SLA implants at week 8 (P = 0.775). The removal torque for the SLM implants at week 8 was further increased. Microscale finite element analysis revealed that the rough surface of the SLM implants dispersed harmful strains at the bone-implant interface into the surrounding bone, thereby mitigating the risk of damage to the bone-implant interface. Conclusions: The rough surface of 3D-printed titanium implants fosters microscale bone interlocking and alleviates peri-implant bone strain concentration, which is a promising biomechanical basis for osseointegration strength.

源语言英语
期刊论文编号208
期刊BMC Oral Health
25
1
DOI
出版状态已出版 - 12月 2025

学术指纹

探究 'Microscale bone interlocking enhances osseointegration strength on the rough surface of 3D-printed titanium implants: experimental and finite element analysis' 的科研主题。它们共同构成独一无二的学术指纹。

引用此