TY - JOUR
T1 - Microfabricated vapor cells with chemical polishing and two-step low-temperature anodic bonding for single-beam magnetometer
AU - Wang, Yanbin
AU - Chen, Yao
AU - Yu, Mingzhi
AU - Ma, Yintao
AU - Han, Xiangguang
AU - Zhao, Libo
AU - Lu, Shun
AU - Guo, Ju
AU - Yang, Ping
AU - Lin, Qijing
N1 - Publisher Copyright:
© 2024 Elsevier Ltd
PY - 2025/2/1
Y1 - 2025/2/1
N2 - With the miniaturization of quantum sensors, the fabrication of alkali metal vapor cells based on micro-electromechanical systems (MEMS) has become increasingly important. However, the fabrication of MEMS vapor cells remains a challenge. In this study, a microfabricated millimeter-level vapor cell was fabricated and tested. The silicon cavity was fabricated by dry etching and chemical polishing. After injection of alkali metal and buffer gas, a two-step low-temperature anodic bonding was employed. The first step was non-isothermal to keep the alkali metal in the low-temperature pole plate and the second step was isothermal to improve the bonding strength, enhancing the hermeticity. Then, the vapor cell was tested for sidewall roughness, bonding strength, and leakage rate. Subsequently, Rb D1 line absorption spectroscopy, stability, and the single-beam magnetometer signal were tested. The results show the fabricated vapor cell had high stability, providing a basis for the miniaturization of quantum devices.
AB - With the miniaturization of quantum sensors, the fabrication of alkali metal vapor cells based on micro-electromechanical systems (MEMS) has become increasingly important. However, the fabrication of MEMS vapor cells remains a challenge. In this study, a microfabricated millimeter-level vapor cell was fabricated and tested. The silicon cavity was fabricated by dry etching and chemical polishing. After injection of alkali metal and buffer gas, a two-step low-temperature anodic bonding was employed. The first step was non-isothermal to keep the alkali metal in the low-temperature pole plate and the second step was isothermal to improve the bonding strength, enhancing the hermeticity. Then, the vapor cell was tested for sidewall roughness, bonding strength, and leakage rate. Subsequently, Rb D1 line absorption spectroscopy, stability, and the single-beam magnetometer signal were tested. The results show the fabricated vapor cell had high stability, providing a basis for the miniaturization of quantum devices.
KW - Atomic magnetometer
KW - Chemical polishing
KW - MEMS alkali metal vapor cell
KW - Two-step low-temperature anodic bonding
UR - https://www.scopus.com/pages/publications/85203816709
U2 - 10.1016/j.measurement.2024.115744
DO - 10.1016/j.measurement.2024.115744
M3 - 文章
AN - SCOPUS:85203816709
SN - 0263-2241
VL - 241
JO - Measurement: Journal of the International Measurement Confederation
JF - Measurement: Journal of the International Measurement Confederation
M1 - 115744
ER -