跳到主要导航 跳到搜索 跳到主要内容

Micro-drop mixer driven by standing surface acoustic waves (SSAW)

  • Miao Baogang
  • , Wang Chaohui
  • , Zheng Tengfei
  • , Zhang Qunming
  • , Jiang Zhuangde
  • Xi'an Jiaotong University

科研成果: 书/报告/会议事项章节 › 会议稿件 › 同行评审

摘要

High-frequency surface acoustic waves (SAW) were generated and transmitted along single-crystal lithium niobate (LiNbO3). The standing surface waves (SSAW) formed between two parallel inter-digital transducers (IDTs) on a LiNbO3 substrate, were employed to drive the micro-drop mixer. An SSAW device was designed, micro-machined and tested. When an AC signal with the frequency of 61.4MHz was applied to the IDTs, vortex appeared in the drop consisted of two incompatible liquid (ink and glycerol). The evolution of the vortex was recorded in this work. With the evolution of the vortex, mixing process of two incompatible liquid has been demonstrated. The mixer is of significant relevance for many bio-technological applications and in particular for lab-on-chip. While the experimental liquids were mutually incompatible, the ink could only be divided into smaller drops.

源语言英语
主期刊名Material Sciences and Manufacturing Technology
页521-523
页数3
DOI
出版状态已出版 - 2013
活动2012 International Conference on Material Sciences and Manufacturing Technology, ICMSMT 2012 - Dalian, 中国
期限: 5 10月 2012 → 6 10月 2012

丛书

姓名Advanced Materials Research
卷629
ISSN(印刷版)1022-6680

会议

会议2012 International Conference on Material Sciences and Manufacturing Technology, ICMSMT 2012
国家/地区中国
市Dalian
时期5/10/12 → 6/10/12