T1 - Micro-CT evaluation and histological analysis of screw-bone interface of expansive pedicle screw in osteoporotic sheep
AU - Wan, Shi Yong
AU - Lei, Wei
AU - Wu, Zi Xiang
AU - Lü, Rong
AU - Wang, Jun
AU - Fu, Suo Chao
AU - Li, Bo
AU - Zhan, Ce
PY - 2008/4/1
Y1 - 2008/4/1
N2 - Objective: To investigate the properties of screwbone interface of expansive pedicle screw (EPS) in osteoporotic sheep by micro-CT and histological observation. Methods: Six female sheep with bilateral ovariectomy-induced osteoporosis were employed in this experiment. After EPS insertion in each femoral condyle, the sheep were randomly divided into two groups: 3 sheep were bred for 3 months (Group A), while the other 3 were bred for 6 months (Group B). After the animals being killed, the femoral condyles with EPS were obtained, which were three-dimensionally-imaged and reconstructed by micro-CT. Histological evaluation was made thereafter. Results: The trabecular microstructure was denser at the screw-bone interface than in the distant parts in expansive section, especially within the spiral marking. In the non-expansive section, however, there was no significant difference between the interface and the distant parts. The regions of interest (ROI) adjacent to EPS were reconstructed and analyzed by micro-CT with the same thresholds. The three-dimensional (3-D) parameters, including tissue mineral density (TMD), bone volume fraction (BVF, BV/TV), bone surface/bone volume (BS/BV) ratio, trabecular thickness (Tb.Th), and trabecular separation (Th.Sp), were significantly better in expansive sections than non-expansive sections (P<0.05). Histologically, newly-formed bony trabeculae crawled along the expansive fissures and into the center of EPS. The newly-formed bones, as well as the bones at the bone-screw interface, closely contacted with the EPS and constructed four compartments. Conclusions: The findings of the current study, based on micro-CT and histological evaluation, suggest that EPS can significantly provide stabilization in osteoporotic cancellous bones.
AB - Objective: To investigate the properties of screwbone interface of expansive pedicle screw (EPS) in osteoporotic sheep by micro-CT and histological observation. Methods: Six female sheep with bilateral ovariectomy-induced osteoporosis were employed in this experiment. After EPS insertion in each femoral condyle, the sheep were randomly divided into two groups: 3 sheep were bred for 3 months (Group A), while the other 3 were bred for 6 months (Group B). After the animals being killed, the femoral condyles with EPS were obtained, which were three-dimensionally-imaged and reconstructed by micro-CT. Histological evaluation was made thereafter. Results: The trabecular microstructure was denser at the screw-bone interface than in the distant parts in expansive section, especially within the spiral marking. In the non-expansive section, however, there was no significant difference between the interface and the distant parts. The regions of interest (ROI) adjacent to EPS were reconstructed and analyzed by micro-CT with the same thresholds. The three-dimensional (3-D) parameters, including tissue mineral density (TMD), bone volume fraction (BVF, BV/TV), bone surface/bone volume (BS/BV) ratio, trabecular thickness (Tb.Th), and trabecular separation (Th.Sp), were significantly better in expansive sections than non-expansive sections (P<0.05). Histologically, newly-formed bony trabeculae crawled along the expansive fissures and into the center of EPS. The newly-formed bones, as well as the bones at the bone-screw interface, closely contacted with the EPS and constructed four compartments. Conclusions: The findings of the current study, based on micro-CT and histological evaluation, suggest that EPS can significantly provide stabilization in osteoporotic cancellous bones.
KW - Expansive pedicle screws
KW - Micro-CT
KW - Osteoporosis
KW - Screw-bone interface
KW - Three-dimensional parameters
UR - https://www.scopus.com/pages/publications/42449130495
U2 - 10.1016/S1008-1275(08)60016-4
DO - 10.1016/S1008-1275(08)60016-4
M3 - 文章
C2 - 18377708
AN - SCOPUS:42449130495
SN - 1008-1275
VL - 11
SP - 72
EP - 77
JO - Chinese Journal of Traumatology - English Edition
JF - Chinese Journal of Traumatology - English Edition
IS - 2
ER -