跳到主要导航 跳到搜索 跳到主要内容

Mammography diagnosis of breast cancer screening through machine learning: a systematic review and meta-analysis

  • Junjie Liu
  • , Jiangjie Lei
  • , Yuhang Ou
  • , Yilong Zhao
  • , Xiaofeng Tuo
  • , Baoming Zhang
  • , Mingwang Shen
  • Xi'an Jiaotong University

科研成果: 期刊稿件文章同行评审

32 引用 (Scopus)

摘要

Breast cancer was the fourth leading cause of cancer-related death worldwide, and early mammography screening could decrease the breast cancer mortality. Artificial intelligence (AI)-assisted diagnose system based on machine learning (ML) methods can help improve the screening accuracy and efficacy. This study aimed to systematically review and make a meta-analysis on the diagnostic accuracy of mammography diagnosis of breast cancer through various ML methods. Springer Link, Science Direct (Elsevier), IEEE Xplore, PubMed and Web of Science were searched for relevant studies published from January 2000 to September 2021. The study was registered with the PROSPERO International Prospective Register of Systematic Reviews (protocol no. CRD42021284227). A Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) was used to assess the included studies, and reporting was evaluated using the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA). The pooled summary estimates for sensitivity, specificity, the area under the receiver operating characteristic curve (AUC) for three ML methods (convolutional neural network [CNN], artificial neural network [ANN], support vector machine [SVM]) were calculated. A total of 32 studies with 23,804 images were included in the meta-analysis. The overall pooled estimate for sensitivity, specificity and AUC was 0.914 [95% CI 0.868–0.945], 0.916 [95% CI 0.873–0.945] and 0.945 for mammography diagnosis of breast cancer through three ML methods. The pooled sensitivity, specificity and AUC of CNN were 0.961 [95% CI 0.886–0.988], 0.950 [95% CI 0.924–0.967] and 0.974. The pooled sensitivity, specificity and AUC of ANN were 0.837 [95% CI 0.772–0.886], 0.894 [95% CI 0.764–0.957] and 0.881. The pooled sensitivity, specificity and AUC of SVM were 0.889 [95% CI 0.807–0.939], 0.843 [95% CI 0.724–0.916] and 0.913. Machine learning methods (especially CNN) show excellent performance in mammography diagnosis of breast cancer screening based on retrospective studies. More rigorous prospective studies are needed to evaluate the longitudinal performance of AI.

源语言英语
页(从-至)2341-2356
页数16
期刊Clinical and Experimental Medicine
23
6
DOI
出版状态已出版 - 10月 2023

联合国可持续发展目标

此成果有助于实现下列可持续发展目标:

  1. 可持续发展目标 3 - 良好健康与福祉
    可持续发展目标 3 良好健康与福祉

学术指纹

探究 'Mammography diagnosis of breast cancer screening through machine learning: a systematic review and meta-analysis' 的科研主题。它们共同构成独一无二的指纹。

引用此