跳到主要导航 跳到搜索 跳到主要内容

Low-dose dynamic myocardial perfusion CT imaging using a motion adaptive sparsity prior

  • Zhaoying Bian
  • , Dong Zeng
  • , Zhang Zhang
  • , Changfei Gong
  • , Xiumei Tian
  • , Gang Yan
  • , Jing Huang
  • , Hong Guo
  • , Bo Chen
  • , Jing Zhang
  • , Qianjin Feng
  • , Wufan Chen
  • , Jianhua Ma
  • Southern Medical University
  • Tianjin Medical University
  • Shenzhen University

科研成果: 期刊稿件 › 文章 › 同行评审

11 引用 (Scopus)

摘要

Purpose: Dynamic myocardial perfusion computed tomography (DM-PCT) imaging offers benefits over quantitative assessment of myocardial blood flow (MBF) for diagnosis and risk stratification of coronary artery disease. However, one major drawback of DM-PCT imaging is that a high radiation level is imparted by repeated scanning. To address this issue, in this work, we developed a statistical iterative reconstruction algorithm based on the penalized weighted least-squares (PWLS) scheme by incorporating a motion adaptive sparsity prior (MASP) model to achieve high-quality DM-PCT imaging with low tube current dynamic data acquisition. For simplicity, we refer to the proposed algorithm as "PWLS-MASP''. Methods: The MASP models both the spatial and temporal structured sparsity of DM-PCT sequence images with the assumption that the differences between adjacent frames after motion correction are sparse in the gradient image domain. To validate and evaluate the effectiveness of the present PWLS-MASP algorithm thoroughly, a modified XCAT phantom and preclinical porcine DM-PCT dataset were used in the study. Results: The present PWLS-MASP algorithm can obtain high-quality DM-PCT images in both phantom and porcine cases, and outperforms the existing filtered back-projection algorithm and PWLS-based algorithms with total variation regularization (PWLS-TV) and robust principal component analysis regularization (PWLS-RPCA) in terms of noise reduction, streak artifacts mitigation, and time density curve estimation. Moreover, the PWLS-MASP algorithm can yield more accurate diagnostic hemodynamic parametric maps than the PWLS-TV and PWLS-RPCA algorithms. Conclusions: The study indicates that there is a substantial advantage in using the present PWLS-MASP algorithm for low-dose DM-PCT, and potentially in other dynamic tomography areas.

源语言英语
页(从-至)e188-e201
期刊Medical Physics
卷44
期9
DOI
出版状态已出版 - 9月 2017
已对外发布是

学术指纹

探究 'Low-dose dynamic myocardial perfusion CT imaging using a motion adaptive sparsity prior' 的科研主题。它们共同构成独一无二的学术指纹。

引用此