跳到主要导航 跳到搜索 跳到主要内容

Low cycle fatigue behavior of stress-aged TB3 alloy

  • Jiangsu Provincial Key Laboratory for Interventional Medical Devices
  • Xi'an Jiaotong University
  • Shaoxing University

科研成果: 期刊稿件文章同行评审

1 引用 (Scopus)

摘要

After solution treatment, Ti-10Mo-8V-1Fe-3.5Al (TB3) alloy was aged at 500°C under a compressive stress. TEM results show that several α variants are observed in conventionally aged samples. However, in the stress-aged TB3 samples, most α plates are parallel to each other in one β grain, which indicates a variant selection effect. Two kinds of TB3 samples were selected for low cycle fatigue tests, which had been heat treated to the same strength level. The one was conventionally aged at 500°C for 9 h, and the other was aged at 500°C for 6 h with about 200 MPa compressive stress. Low cycle fatigue (LCF) test results show that the stress-aged TB3 samples exhibit a longer LCF lifetime than the conventionally aged ones.

源语言英语
页(从-至)2153-2156
页数4
期刊Xiyou Jinshu Cailiao Yu Gongcheng/Rare Metal Materials and Engineering
42
10
出版状态已出版 - 10月 2013

学术指纹

探究 'Low cycle fatigue behavior of stress-aged TB3 alloy' 的科研主题。它们共同构成独一无二的学术指纹。

引用此