TY - JOUR
T1 - LCL resonant current depression control strategy against pulse width modulated harmonic voltage under low switching frequency
AU - Ma, Zhijun
AU - Zhou, Linyuan
AU - Liu, Jinjun
AU - Zhou, Sizhan
N1 - Publisher Copyright:
© 2020, The Korean Institute of Power Electronics.
PY - 2021/2
Y1 - 2021/2
N2 - The LCL filter is widely used in grid connected converters for good harmonic mitigation performance. With pulse width modulation strategy, converter terminal voltage contains various sideband harmonic components together with expected components corresponding to the modulation wave, especially under a low switching frequency. Considerable resonant current can be generated if the undesired sideband harmonic voltage is located around the LCL resonant frequency. With the background of a medium voltage three-level wind power converter, where the switching frequency is as low as 1.5 kHz, a resonant current depression strategy is proposed against undesired sideband harmonic voltage under low switching frequency. Additional compensators are adopted in the converter current loop. Depending on the system mathematical model, two solutions, a Butterworth low pass filter and a notch filter, based on phase compensation and amplitude compensation, are proposed in this paper. It is shown that the Butterworth low pass filter exhibits better resonant current depression performance, while the notch filter performance is better in terms of system stability. Simulation and experimental results validated the proposed control method.
AB - The LCL filter is widely used in grid connected converters for good harmonic mitigation performance. With pulse width modulation strategy, converter terminal voltage contains various sideband harmonic components together with expected components corresponding to the modulation wave, especially under a low switching frequency. Considerable resonant current can be generated if the undesired sideband harmonic voltage is located around the LCL resonant frequency. With the background of a medium voltage three-level wind power converter, where the switching frequency is as low as 1.5 kHz, a resonant current depression strategy is proposed against undesired sideband harmonic voltage under low switching frequency. Additional compensators are adopted in the converter current loop. Depending on the system mathematical model, two solutions, a Butterworth low pass filter and a notch filter, based on phase compensation and amplitude compensation, are proposed in this paper. It is shown that the Butterworth low pass filter exhibits better resonant current depression performance, while the notch filter performance is better in terms of system stability. Simulation and experimental results validated the proposed control method.
KW - Active damping
KW - Anti-aliasing filter
KW - Resonant current depression
KW - Sideband harmonic voltage
UR - https://www.scopus.com/pages/publications/85097432031
U2 - 10.1007/s43236-020-00190-9
DO - 10.1007/s43236-020-00190-9
M3 - 文章
AN - SCOPUS:85097432031
SN - 1598-2092
VL - 21
SP - 416
EP - 426
JO - Journal of Power Electronics
JF - Journal of Power Electronics
IS - 2
ER -