TY - JOUR
T1 - Large piezoelectric anisotropy and enhanced hydrostatic properties of lead metaniobate for high-sensitivity receiving transducers
AU - Jin, Ruoqi
AU - Hu, Liqing
AU - Qiu, Chenyu
AU - Wang, Sanhong
AU - Xu, Zhuo
AU - Yan, Yongke
N1 - Publisher Copyright:
© 2026 Elsevier B.V. All rights are reserved, including those for text and data mining, AI training, and similar technologies.
PY - 2026/4/16
Y1 - 2026/4/16
N2 - Lead metaniobate (PbNb2O6, PN) ceramics are promising candidates for high-temperature receiving transducers due to their high Curie temperature, low permittivity, and low mechanical quality factor. However, the mechanical loss in PN ceramics renders the conventional IEEE resonance method ineffective, leading to substantial overestimation of electromechanical coupling coefficient (k31). This study employs a complex-parameter global fitting method to accurately determine the piezoelectric properties of PN ceramics from impedance spectra. The results verified the strong piezoelectric anisotropy in PN ceramics with a k33/k31 ratio of 5.61, which is consistent with the high |d33/d31| ratio obtained by the quasi-static method. In addition, the temperature-dependent behavior of PN ceramics is measured from 25 °C to 260 °C. The results confirm that PN ceramics exhibit exceptional temperature stability in their dielectric and hydrostatic piezoelectric properties across this wide temperature range. Furthermore, the transducers based on PN and BiScO3-PbTiO3 (BSPT) ceramics were designed through simulation and subsequently fabricated. The PN transducers demonstrate minimal spurious vibrations and a flat frequency response, achieving 14 dB higher sensitivity and significantly better low-frequency stability than the BSPT-based transducers. This superior performance is attributed to the large piezoelectric anisotropy and superior hydrostatic properties of the PN material, conclusively establishing its promise for high-sensitivity receiving transducers.
AB - Lead metaniobate (PbNb2O6, PN) ceramics are promising candidates for high-temperature receiving transducers due to their high Curie temperature, low permittivity, and low mechanical quality factor. However, the mechanical loss in PN ceramics renders the conventional IEEE resonance method ineffective, leading to substantial overestimation of electromechanical coupling coefficient (k31). This study employs a complex-parameter global fitting method to accurately determine the piezoelectric properties of PN ceramics from impedance spectra. The results verified the strong piezoelectric anisotropy in PN ceramics with a k33/k31 ratio of 5.61, which is consistent with the high |d33/d31| ratio obtained by the quasi-static method. In addition, the temperature-dependent behavior of PN ceramics is measured from 25 °C to 260 °C. The results confirm that PN ceramics exhibit exceptional temperature stability in their dielectric and hydrostatic piezoelectric properties across this wide temperature range. Furthermore, the transducers based on PN and BiScO3-PbTiO3 (BSPT) ceramics were designed through simulation and subsequently fabricated. The PN transducers demonstrate minimal spurious vibrations and a flat frequency response, achieving 14 dB higher sensitivity and significantly better low-frequency stability than the BSPT-based transducers. This superior performance is attributed to the large piezoelectric anisotropy and superior hydrostatic properties of the PN material, conclusively establishing its promise for high-sensitivity receiving transducers.
KW - Complex-parameter modeling
KW - High-temperature piezoelectric ceramics
KW - Lead metaniobate
KW - Receiving transducer
UR - https://www.scopus.com/pages/publications/105034359584
U2 - 10.1016/j.sna.2026.117571
DO - 10.1016/j.sna.2026.117571
M3 - 文章
AN - SCOPUS:105034359584
SN - 0924-4247
VL - 401
JO - Sensors and Actuators A: Physical
JF - Sensors and Actuators A: Physical
M1 - 117571
ER -