TY - JOUR
T1 - Investigation on the influence of geometric parameters on two-phase ejector performance with R290
AU - Lu, Yu
AU - Bai, Tao
AU - Yu, Jianlin
N1 - Publisher Copyright:
© 2023
PY - 2023/12
Y1 - 2023/12
N2 - In this paper, the effect of geometric parameters on a two-phase ejector performance was experimentally studied, and the R290 was used as the working fluid. The four geometric parameters of the ejector were discussed in detail, including the diameter of the nozzle throat (Dt), the nozzle exit position (NXP), the diameter of the mixing section (Dm) and the length of the mixing section (Lm). The experimental results indicated that the pressure lift ratio (rp) of the ejector was sensitive to Dt and NXP. Within the increase of Dt and NXP discussed in this paper, the rp of the ejector varied from 1.13 to 1.33 and 1.32 to 1.07, respectively. In addition, a maximum rp of the ejector could be obtained when Dm was 3 mm to 4 mm under different nozzle throat diameter. When the Dt was 0.7 mm, the entrainment ratio of the ejector varied from 0.402 to 1.406 as the Dm varied from 2 mm to 6 mm. The Lm of the ejector diffuser had little effect on the ejector performance. Moreover, the empirical correlations for the efficiencies of R290 two-phase ejector components were summarized based on the experimental result and ejector model.
AB - In this paper, the effect of geometric parameters on a two-phase ejector performance was experimentally studied, and the R290 was used as the working fluid. The four geometric parameters of the ejector were discussed in detail, including the diameter of the nozzle throat (Dt), the nozzle exit position (NXP), the diameter of the mixing section (Dm) and the length of the mixing section (Lm). The experimental results indicated that the pressure lift ratio (rp) of the ejector was sensitive to Dt and NXP. Within the increase of Dt and NXP discussed in this paper, the rp of the ejector varied from 1.13 to 1.33 and 1.32 to 1.07, respectively. In addition, a maximum rp of the ejector could be obtained when Dm was 3 mm to 4 mm under different nozzle throat diameter. When the Dt was 0.7 mm, the entrainment ratio of the ejector varied from 0.402 to 1.406 as the Dm varied from 2 mm to 6 mm. The Lm of the ejector diffuser had little effect on the ejector performance. Moreover, the empirical correlations for the efficiencies of R290 two-phase ejector components were summarized based on the experimental result and ejector model.
KW - Component efficiencies
KW - Empirical correlations
KW - Experimental study
KW - Geometry parameters
KW - Two-phase ejector
UR - https://www.scopus.com/pages/publications/85173843129
U2 - 10.1016/j.ijrefrig.2023.09.020
DO - 10.1016/j.ijrefrig.2023.09.020
M3 - 文章
AN - SCOPUS:85173843129
SN - 0140-7007
VL - 156
SP - 102
EP - 112
JO - International Journal of Refrigeration
JF - International Journal of Refrigeration
ER -