摘要
A prototype of loop heat pipe with the composite capillary evaporator was developed to investigate the operational characteristics of the novel structure LHP. The thermal behaviors of the LHP corresponding to the start-up and variation of the heat load were experimentally studied. The thermal resistance and the temperature oscillation phenomena were also analyzed. The comparison of the operational characteristics between the composite capillary evaporator and single capillary evaporator revealed that the LHP with composite capillary evaporator has higher heat transfer capability and smaller thermal resistance than those of conventional LHP with single structure capillary evaporator. But the temperature oscillation was intensified for the LHP with composite capillary evaporator during the start-up process at the small input heat load.
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 148-150 |
| 页数 | 3 |
| 期刊 | Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics |
| 卷 | 29 |
| 期 | 1 |
| 出版状态 | 已出版 - 1月 2008 |