Ionic liquid compressors are the ideal solution for hydrogen refueling stations, and multi-stage compression is an inevitable choice for achieving high-pressure refueling, such as 90 MPa level. However, the initial filling amount of the ionic liquid in the compression chamber is lacking basis as the characteristics of gas-liquid two-phase flow during the reciprocating movement of the liquid piston are not understood. This study numerically investigates the variation characteristics of the gas-liquid interface in the compression chambers under different structural and operating parameters of a five-stage ionic liquid compressor. Based on the fluctuation feature of the phase interface, the minimum liquid piston heights in each stage that ensure effective sealing for the compression chamber with different stroke-to-diameter ratios (r) are determined. Finally, the mathematical relationship for calculating the minimum ionic liquid filling amount related to structural parameter r and suction pressure is established, which provides guidance for the design of the ionic liquid compressor.