TY - JOUR
T1 - Investigation of laser-induced plasma at varying pressure and laser focusing
AU - Yuan, Huan
AU - Gojani, Ardian B.
AU - Gornushkin, Igor B.
AU - Wang, Xiaohua
N1 - Publisher Copyright:
© 2018 Elsevier B.V.
PY - 2018/12
Y1 - 2018/12
N2 -
Expansion dynamics of laser-induced plasma is studied for different focal positions of the ablation laser in the pressure range 10
-2
- 10
5
Pa of the ambient air. The experimental results indicate that both the parameters significantly affect the plasma size, shape, intensity, reproducibility, and distance from the target surface. At pressures above 10 Pa, the plasma plume is confined by the ambient gas; the plumes are more compact and travel shorter distances from the target as compared to the analogous plume characteristics at pressures below 10 Pa. The pulse-to-pulse reproducibility of the integral emission intensity of the plasma is also different for different focal positions and pressures. It is found that the focal positions -1 cm and -2 cm below the target surface yield the most reproducible and intense emission signals as measured at the 600 ns delay time with the 100 ns gate. The information obtained can be of importance for pulsed laser deposition, laser welding, and analytical spectroscopy at reduced pressures. In general, a correct choice of the focal position and pressure of an ambient gas is very important for obtaining the strongest plasma emission, good reproducibility, and desired plasma plume shape.
AB -
Expansion dynamics of laser-induced plasma is studied for different focal positions of the ablation laser in the pressure range 10
-2
- 10
5
Pa of the ambient air. The experimental results indicate that both the parameters significantly affect the plasma size, shape, intensity, reproducibility, and distance from the target surface. At pressures above 10 Pa, the plasma plume is confined by the ambient gas; the plumes are more compact and travel shorter distances from the target as compared to the analogous plume characteristics at pressures below 10 Pa. The pulse-to-pulse reproducibility of the integral emission intensity of the plasma is also different for different focal positions and pressures. It is found that the focal positions -1 cm and -2 cm below the target surface yield the most reproducible and intense emission signals as measured at the 600 ns delay time with the 100 ns gate. The information obtained can be of importance for pulsed laser deposition, laser welding, and analytical spectroscopy at reduced pressures. In general, a correct choice of the focal position and pressure of an ambient gas is very important for obtaining the strongest plasma emission, good reproducibility, and desired plasma plume shape.
KW - Imaging
KW - Laser-induced plasma
KW - Plasma expansion
UR - https://www.scopus.com/pages/publications/85054440719
U2 - 10.1016/j.sab.2018.10.005
DO - 10.1016/j.sab.2018.10.005
M3 - 文章
AN - SCOPUS:85054440719
SN - 0584-8547
VL - 150
SP - 33
EP - 37
JO - Spectrochimica Acta - Part B Atomic Spectroscopy
JF - Spectrochimica Acta - Part B Atomic Spectroscopy
ER -