TY - JOUR
T1 - Investigation of heat transfer behavior of high-temperature heat pipes under transient input power conditions
AU - Zhang, Jiarui
AU - Mou, Yuankun
AU - Guo, Kailun
AU - Hei, Zihao
AU - Wang, Chenglong
AU - Tian, Wenxi
AU - Qiu, Suizheng
AU - Su, Guanghui
N1 - Publisher Copyright:
© 2026 Elsevier Ltd.
PY - 2026/4
Y1 - 2026/4
N2 - High-temperature heat pipes (HTHPs) are efficient passive heat transfer devices crucial for high-performance thermal management. Under complex thermal environments, HTHPs often face transient conditions such as sudden power fluctuations, making their thermal stability and structural integrity critical. This study systematically examined the transient responses of liquid-metal HTHPs under three scenarios: steady-state startup with cooling, sudden power increase, and sudden power decrease. Experiments were performed on a self-developed platform allowing real-time monitoring of axial temperature along the evaporator, adiabatic, and condenser sections. Two sodium HTHPs of different specifications were designed and fabricated. Both exhibited excellent thermal conduction and uniform temperature distribution during steady-state startup, reaching maximum cooling powers of 6.42 kW and 3.71 kW. The axial temperature increased smoothly with negligible lag, and startup length exceeded 90%, indicating stable capillary return and vapor-liquid circulation. Under large-amplitude power surges, the evaporator temperature spiked up to 150 °C at 3.57 °C/s, while the condenser showed notable cooling. A power surge safety factor S was defined as the threshold for stable operation. Exceeding this limit caused imbalance between vapor flow and capillary return, resulting in dry-out, local overheating, and thermal gradients threatening structural integrity. During moderate power drops, working fluid circulation and phase-change heat transfer remained stable, with minor temperature oscillations. However, abrupt reduction to zero followed by restart generated severe thermal stress in the evaporator, causing local dry-out and permanent capillary damage, as shown by significant midsection overheating. In summary, this work provides a clear understanding of transient thermal responses and failure mechanisms in HTHPs under sudden power changes. The findings offer guidance for safe design, stability assessment, and operational control of high-temperature passive heat transfer systems.
AB - High-temperature heat pipes (HTHPs) are efficient passive heat transfer devices crucial for high-performance thermal management. Under complex thermal environments, HTHPs often face transient conditions such as sudden power fluctuations, making their thermal stability and structural integrity critical. This study systematically examined the transient responses of liquid-metal HTHPs under three scenarios: steady-state startup with cooling, sudden power increase, and sudden power decrease. Experiments were performed on a self-developed platform allowing real-time monitoring of axial temperature along the evaporator, adiabatic, and condenser sections. Two sodium HTHPs of different specifications were designed and fabricated. Both exhibited excellent thermal conduction and uniform temperature distribution during steady-state startup, reaching maximum cooling powers of 6.42 kW and 3.71 kW. The axial temperature increased smoothly with negligible lag, and startup length exceeded 90%, indicating stable capillary return and vapor-liquid circulation. Under large-amplitude power surges, the evaporator temperature spiked up to 150 °C at 3.57 °C/s, while the condenser showed notable cooling. A power surge safety factor S was defined as the threshold for stable operation. Exceeding this limit caused imbalance between vapor flow and capillary return, resulting in dry-out, local overheating, and thermal gradients threatening structural integrity. During moderate power drops, working fluid circulation and phase-change heat transfer remained stable, with minor temperature oscillations. However, abrupt reduction to zero followed by restart generated severe thermal stress in the evaporator, causing local dry-out and permanent capillary damage, as shown by significant midsection overheating. In summary, this work provides a clear understanding of transient thermal responses and failure mechanisms in HTHPs under sudden power changes. The findings offer guidance for safe design, stability assessment, and operational control of high-temperature passive heat transfer systems.
KW - Experimental study
KW - High-temperature heat pipe
KW - Power transient
UR - https://www.scopus.com/pages/publications/105030868902
U2 - 10.1016/j.applthermaleng.2026.130206
DO - 10.1016/j.applthermaleng.2026.130206
M3 - 文章
AN - SCOPUS:105030868902
SN - 1359-4311
VL - 292
JO - Applied Thermal Engineering
JF - Applied Thermal Engineering
M1 - 130206
ER -