跳到主要导航 跳到搜索 跳到主要内容

Integrated Operating Scenario to Achieve 100-Second, High Electron Temperature Discharge on EAST

  • The EAST Team
  • CAS - Institute of Plasma Physics

科研成果: 期刊稿件 › 文章 › 同行评审

38 引用 (Scopus)

摘要

Stationary long pulse plasma of high electron temperature was produced on EAST for the first time through an integrated control of plasma shape, divertor heat flux, particle exhaust, wall conditioning, impurity management, and the coupling of multiple heating and current drive power. A discharge with a lower single null divertor configuration was maintained for 103 s at a plasma current of 0.4 MA, q95 ≈7.0, a peak electron temperature of >4.5 keV, and a central density ne(0)∼2.5×1019 m-3. The plasma current was nearly non-inductive (Vloop <0.05 V, poloidal beta ∼ 0.9) driven by a combination of 0.6 MW lower hybrid wave at 2.45 GHz, 1.4 MW lower hybrid wave at 4.6 GHz, 0.5 MW electron cyclotron heating at 140 GHz, and 0.4 MW modulated neutral deuterium beam injected at 60 kV. This progress demonstrated strong synergy of electron cyclotron and lower hybrid electron heating, current drive, and energy confinement of stationary plasma on EAST. It further introduced an example of integrated "hybrid" operating scenario of interest to ITER and CFETR.

源语言英语
页(从-至)457-459
页数3
期刊Plasma Science and Technology
卷18
期5
DOI
出版状态已出版 - 5月 2016

学术指纹

探究 'Integrated Operating Scenario to Achieve 100-Second, High Electron Temperature Discharge on EAST' 的科研主题。它们共同构成独一无二的学术指纹。

引用此