跳到主要导航 跳到搜索 跳到主要内容

Integrated behavior of carbon and copper alloy heat sink under different heat loads and cooling conditions

  • Li Hua
  • , Li Jiangang
  • , Chen Junling
  • , Hu Jiansheng
  • CAS - Institute of Plasma Physics

科研成果: 期刊稿件文献综述同行评审

4 引用 (Scopus)

摘要

An actively water-cooled limiter has been designed for the long pulse operation of an HT-7 device, by adopting an integrated structure-doped graphite and a copper alloy heat sink with a super carbon sheet serving as a compliant layer between them. The behaviors of the integrated structure were evaluated in an electron beam facility under different heat loads and cooling conditions. The surface temperature and bulk temperature distribution were carefully measured by optical pyrometers and thermocouples under a steady state heat flux of 1 to 5 MW/m2 and a water flow rate of 3 m3/h, 4.5 m 3/h and 6 m3/h, respectively. It was found that the surface temperature increased rapidly with the heat flux rising, but decreased only slightly with the water flow rate rising. The surface temperature reached approximately 1200°C at 5 MW/m2 of heat flux and 6 m 3/h of water flow. The primary experimental results indicate that the integrated design meets the requirements for the heat expelling capacity of the HT-7 device. A set of numerical simulations was also completed, whose outcome was in good accord with the experimental results. HT-7 tokamak, carbon and copper alloy heat sink, heat.

源语言英语
页(从-至)2923-2925
页数3
期刊Plasma Science and Technology
7
4
DOI
出版状态已出版 - 8月 2005

学术指纹

探究 'Integrated behavior of carbon and copper alloy heat sink under different heat loads and cooling conditions' 的科研主题。它们共同构成独一无二的指纹。

引用此