跳到主要导航 跳到搜索 跳到主要内容

Inactivation Effect of Low-Temperature Plasma on Pseudomonas aeruginosa for Nosocomial Anti-Infection

  • Xing Min Shi
  • , Wen Long Liao
  • , Zheng Shi Chang
  • , Guan Jun Zhang
  • , Xi Li Wu
  • , Xiao Feng Dong
  • , Cong Wei Yao
  • , Bing Yu Ye
  • , Ping Li
  • , Gui Min Xu
  • , Si Le Chen
  • , Jing Fen Cai
  • Xi'an Jiaotong University
  • Key Laboratory for Disease Prevention and Control and Health Promotion of Shaanxi Province

科研成果: 期刊稿件文章同行评审

8 引用 (Scopus)

摘要

Disinfection and sterilization in hospitals and other public places have always been the focus of attention. In our studies, dielectric barrier corona discharge (DBCD) was used to generate low-temperature plasma (LTP) to treat Pseudomonas aeruginosa (P. aeruginosa, one kind of bacteria responsible for nosocomial infections). The survival colonies of P. aeruginosa were counted with the standard plate-counting method after 30-, 60-, 90-, and 120-s exposures to DBCD. We discovered that LTP could lead to more than 5-log reduction of P. aeruginosa after 120-s treatment. Further experiments indicated that OH and excited N2 in LTP and lower pH value in bacterial suspension might synergistically inactivate P. aeruginosa by destroying its outer structure.