TY - JOUR
T1 - Improvement of the spatial resolution of the spatial mapping of metallic coatings by using picosecond LIBS
AU - Wang, Zhenzhen
AU - Shen, Sijie
AU - Arima, Yuta
AU - Li, Chi
AU - Zhou, Wangzheng
AU - Li, Shoujie
AU - Yan, Junjie
AU - Deguchi, Yoshihiro
N1 - Publisher Copyright:
© 2024 Elsevier B.V.
PY - 2024/10
Y1 - 2024/10
N2 - Laser-induced breakdown spectroscopy (LIBS) has been widely applied in various fields such as environmental monitoring, materials science, and archaeological research. The current research focuses on improving the spatial resolution of elemental spatial imaging by using LIBS. The nanosecond laser is commonly used in LIBS. During the nanosecond laser ablation process, there is a thermal effect on the target material, making it difficult to further improve the spatial resolution. This study used a picosecond laser to investigate the effects of the diameter of laser focusing spot, laser energy, and laser irradiation interval on the spatial resolution of LIBS. The spatial mapping of metallic coatings by using LIBS with a spatial resolution of 1 μm was achieved by using laser energy of 0.4 μJ/pulse and irradiation interval of 0.8 μm. The LIBS measurement results are in good agreement with the scanning electron microscopy energy dispersive X-ray spectroscopy (SEM-EDS) results. This research shows that by changing the laser ablation conditions, the spatial resolution of the spatial mapping of metallic coatings by using LIBS based on picosecond laser can be reduced to 1 μm or lower.
AB - Laser-induced breakdown spectroscopy (LIBS) has been widely applied in various fields such as environmental monitoring, materials science, and archaeological research. The current research focuses on improving the spatial resolution of elemental spatial imaging by using LIBS. The nanosecond laser is commonly used in LIBS. During the nanosecond laser ablation process, there is a thermal effect on the target material, making it difficult to further improve the spatial resolution. This study used a picosecond laser to investigate the effects of the diameter of laser focusing spot, laser energy, and laser irradiation interval on the spatial resolution of LIBS. The spatial mapping of metallic coatings by using LIBS with a spatial resolution of 1 μm was achieved by using laser energy of 0.4 μJ/pulse and irradiation interval of 0.8 μm. The LIBS measurement results are in good agreement with the scanning electron microscopy energy dispersive X-ray spectroscopy (SEM-EDS) results. This research shows that by changing the laser ablation conditions, the spatial resolution of the spatial mapping of metallic coatings by using LIBS based on picosecond laser can be reduced to 1 μm or lower.
KW - Elemental spatial mapping
KW - Laser-induced breakdown spectroscopy
KW - Picosecond laser
KW - Scanning electron microscope
KW - Spatial resolution
UR - https://www.scopus.com/pages/publications/85201746679
U2 - 10.1016/j.sab.2024.107016
DO - 10.1016/j.sab.2024.107016
M3 - 文章
AN - SCOPUS:85201746679
SN - 0584-8547
VL - 220
JO - Spectrochimica Acta - Part B Atomic Spectroscopy
JF - Spectrochimica Acta - Part B Atomic Spectroscopy
M1 - 107016
ER -