TY - JOUR
T1 - Impact of primary and secondary air supply intensity in stove on emissions of size-segregated particulate matter and carbonaceous aerosols from apple tree wood burning
AU - Sun, Jian
AU - Shen, Zhenxing
AU - Zhang, Leiming
AU - Zhang, Qian
AU - Lei, Yali
AU - Cao, Junji
AU - Huang, Yu
AU - Liu, Suixin
AU - Zheng, Chunli
AU - Xu, Hongmei
AU - Liu, Hongxia
AU - Pan, Hua
AU - Liu, Pingping
AU - Zhang, Renjian
N1 - Publisher Copyright:
© 2017 Elsevier B.V.
PY - 2018/4/1
Y1 - 2018/4/1
N2 - In order to assess emission factors (EF) more accurately from household biomass burning, a series of laboratory-controlled apple tree wood burning tests were conducted to measure the EFs of size-segregated particulate matter (PM) and carbonaceous aerosols. The controlled burning experiments were conducted with designed primary air (PA) and secondary air (SA) supply intensity. An optimum value of 7 m3·h− 1 was found for SA, resulting the highest modified combustion efficiency (92.4 ± 2.5%) as well as the lowest EFs of PM2.5 (0.13 ± 0.01 g·MJ− 1), OC (0.04 ± 0.03 g·MJ− 1) and EC (0.03 ± 0.01 g·MJ− 1). SA values of 7 and 10 m3·h− 1 resulted the lowest EFs for all the different PM sizes. In a test with PA of 6 m3·h− 1 and SA of 7 m3·h− 1, very low EFs were observed for OC1 (8.2%), OC2 (11.2%) and especially OP (Pyrolyzed OC) (0%, not detected), indicating nearly complete combustion under this air supply condition. Besides SA, higher PA was proved to have positive effects on PM and carbonaceous fraction emission reduction. For example, with a fixed SA of 1.5 m3·h− 1, EFs of PM2.5 decreased from 0.64 to 0.27 g·MJ− 1 when PA increased from 6 to 15 m3·h− 1 (P < 0.05). Similar reductions were also observed in EFs of OC, EC and size segregated PM.
AB - In order to assess emission factors (EF) more accurately from household biomass burning, a series of laboratory-controlled apple tree wood burning tests were conducted to measure the EFs of size-segregated particulate matter (PM) and carbonaceous aerosols. The controlled burning experiments were conducted with designed primary air (PA) and secondary air (SA) supply intensity. An optimum value of 7 m3·h− 1 was found for SA, resulting the highest modified combustion efficiency (92.4 ± 2.5%) as well as the lowest EFs of PM2.5 (0.13 ± 0.01 g·MJ− 1), OC (0.04 ± 0.03 g·MJ− 1) and EC (0.03 ± 0.01 g·MJ− 1). SA values of 7 and 10 m3·h− 1 resulted the lowest EFs for all the different PM sizes. In a test with PA of 6 m3·h− 1 and SA of 7 m3·h− 1, very low EFs were observed for OC1 (8.2%), OC2 (11.2%) and especially OP (Pyrolyzed OC) (0%, not detected), indicating nearly complete combustion under this air supply condition. Besides SA, higher PA was proved to have positive effects on PM and carbonaceous fraction emission reduction. For example, with a fixed SA of 1.5 m3·h− 1, EFs of PM2.5 decreased from 0.64 to 0.27 g·MJ− 1 when PA increased from 6 to 15 m3·h− 1 (P < 0.05). Similar reductions were also observed in EFs of OC, EC and size segregated PM.
KW - Carbonaceous aerosol
KW - Emission factors
KW - Secondary air supply
KW - Semi-gasifier stove
KW - Wood burning
UR - https://www.scopus.com/pages/publications/85033664542
U2 - 10.1016/j.atmosres.2017.11.010
DO - 10.1016/j.atmosres.2017.11.010
M3 - 文章
AN - SCOPUS:85033664542
SN - 0169-8095
VL - 202
SP - 33
EP - 39
JO - Atmospheric Research
JF - Atmospheric Research
ER -