摘要
Objective: To establish a high-performance liquid chromatography method for determination of mycophenolic acid in human plasma. Methods: The method was performed with C18 column (3.9 mmX300 mm). The mobile phase consisted of 40 mmoL/L TBA solution-acetonitrile adjusted to pH 4 with orthophosphoric acid (55 : 45, V : V), with a flow rate 0.8 mL/min. The UV detection wavelength was 254 nm. Plasma samples were extracted with methanol. Results The linear concentration of the calibration curve ranged from 0. 8 to 51.45 mg/L (r = 0.9998). The relative recoveries were between 95.5% and 109.2%, and the extraction recoveries were more than 90%. Relative standard deviation (RSD) of intraday and interday assays were both less than 10%. Conclusion: The method is proved to be reliable and simple for monitoring mycophenolic acid in human plasma and bioequivalence research.
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 643-645 |
| 页数 | 3 |
| 期刊 | Journal of Xi'an Jiaotong University (Medical Sciences) |
| 卷 | 30 |
| 期 | 5 |
| 出版状态 | 已出版 - 2009 |