TY - JOUR
T1 - Household Fluorescent Lateral Flow Strip Platform for Sensitive and Quantitative Prognosis of Heart Failure Using Dual-Color Upconversion Nanoparticles
AU - You, Minli
AU - Lin, Min
AU - Gong, Yan
AU - Wang, Shurui
AU - Li, Ang
AU - Ji, Lingyu
AU - Zhao, Haoxiang
AU - Ling, Kai
AU - Wen, Ting
AU - Huang, Yuan
AU - Gao, Dengfeng
AU - Ma, Qiong
AU - Wang, Tingzhong
AU - Ma, Aiqun
AU - Li, Xiaoling
AU - Xu, Feng
N1 - Publisher Copyright:
© 2017 American Chemical Society.
PY - 2017/6/27
Y1 - 2017/6/27
N2 - Heart failure (HF) is the end-stage of cardiovascular diseases, which is associated with a high mortality rate and high readmission rate. Household early diagnosis and real-time prognosis of HF at bedside are of significant importance. Here, we developed a highly sensitive and quantitative household prognosis platform (termed as UC-LFS platform), integrating a smartphone-based reader with multiplexed upconversion fluorescent lateral flow strip (LFS). Dual-color core-shell upconversion nanoparticles (UCNPs) were synthesized as probes for simultaneously quantifying two target antigens associated with HF, i.e., brain natriuretic peptide (BNP) and suppression of tumorigenicity 2 (ST2). With the fluorescent LFS, we achieved the specific detection of BNP and ST2 antigens in spiked samples with detection limits of 5 pg/mL and 1 ng/mL, respectively, both of which are of one order lower than their clinical cutoff. Subsequently, a smartphone-based portable reader and an analysis app were developed, which could rapidly quantify the result and share prognosis results with doctors. To confirm the usage of UC-LFS platform for clinical samples, we detected 38 clinical serum samples using the platform and successfully detected the minimal concentration of 29.92 ng/mL for ST2 and 17.46 pg/mL for BNP in these clinical samples. Comparing the detection results from FDA approved clinical methods, we obtained a good linear correlation, indicating the practical reliability and stability of our developed UC-LFS platform. Therefore, the developed UC-LFS platform is demonstrated to be highly sensitive and specific for sample-to-answer prognosis of HF, which holds great potential for risk assessment and health monitoring of post-treatment patients at home.
AB - Heart failure (HF) is the end-stage of cardiovascular diseases, which is associated with a high mortality rate and high readmission rate. Household early diagnosis and real-time prognosis of HF at bedside are of significant importance. Here, we developed a highly sensitive and quantitative household prognosis platform (termed as UC-LFS platform), integrating a smartphone-based reader with multiplexed upconversion fluorescent lateral flow strip (LFS). Dual-color core-shell upconversion nanoparticles (UCNPs) were synthesized as probes for simultaneously quantifying two target antigens associated with HF, i.e., brain natriuretic peptide (BNP) and suppression of tumorigenicity 2 (ST2). With the fluorescent LFS, we achieved the specific detection of BNP and ST2 antigens in spiked samples with detection limits of 5 pg/mL and 1 ng/mL, respectively, both of which are of one order lower than their clinical cutoff. Subsequently, a smartphone-based portable reader and an analysis app were developed, which could rapidly quantify the result and share prognosis results with doctors. To confirm the usage of UC-LFS platform for clinical samples, we detected 38 clinical serum samples using the platform and successfully detected the minimal concentration of 29.92 ng/mL for ST2 and 17.46 pg/mL for BNP in these clinical samples. Comparing the detection results from FDA approved clinical methods, we obtained a good linear correlation, indicating the practical reliability and stability of our developed UC-LFS platform. Therefore, the developed UC-LFS platform is demonstrated to be highly sensitive and specific for sample-to-answer prognosis of HF, which holds great potential for risk assessment and health monitoring of post-treatment patients at home.
KW - heart failure
KW - household
KW - lateral flow strip
KW - prognosis
KW - smartphone-based reader
KW - upconversion nanoparticle
UR - https://www.scopus.com/pages/publications/85021405184
U2 - 10.1021/acsnano.7b02466
DO - 10.1021/acsnano.7b02466
M3 - 文章
C2 - 28482150
AN - SCOPUS:85021405184
SN - 1936-0851
VL - 11
SP - 6261
EP - 6270
JO - ACS Nano
JF - ACS Nano
IS - 6
ER -