跳到主要导航 跳到搜索 跳到主要内容

High-Sensitivity, Low-Field 19F-MRI Approach Using High Manganese Ferrite Concentrations

  • Yupeng Cao
  • , Xiaohan Zhou
  • , Xiaoli Liu
  • , Mei Yang
  • , Wentao Liu
  • , Dong Han
  • National Center for Nanoscience and Technology
  • University of Chinese Academy of Sciences
  • The First Affiliated Hospital of Xi’an Jiaotong University
  • CAS - Institute of Process Engineering

科研成果: 期刊稿件文章同行评审

4 引用 (Scopus)

摘要

Fluorine-19 (19F) MRI (19F-MRI) is a promising method for quantifying biomedical research and clinical applications without background interference. Nevertheless, dependency on high-field MRI systems limits the applicability of 19F-MRI. Low-field MRI systems are more common than high-field MRI systems. Hence, developing 19F-MRI at low-field MRI devices can promote the 19F-MRI translation in medical diagnosis. The detection sensitivity of fluorine agents is critical in 19F-MRI. Reduction of the 19F spin-lattice relaxation time (T1) enables an improved detection sensitivity while requiring ultrashort echo time (UTE) imaging methods to reduce the negative spin-spin relaxation (T2) decay effect. However, conventional UTE sequences require hardware with high performance. Herein, we introduce the k-space scaling imaging (KSSI) MRI sequence that accomplishes sampling k-space with variable scales to implement hardware-friendly UTE 19F-MRI compatible with low-field MRI systems. We implemented experiments with swine bone, a perfluorooctyl bromide (PFOB) phantom, and one tumor-bearing mouse on two self-customized low-field MRI systems. The swine bone imaging validated the ultrashort TE of KSSI. Under high concentrations of manganese ferrite, a high signal-to-noise ratio was shown in the imaging of a fluorine atom concentration of 658 mM, which indicated high-sensitivity detection of KSSI. Moreover, the KSSI sequence exhibited a 7.1 times signal-to-noise ratio of spin echo sequence on the PFOB phantom imaging with a fluorine atom concentration of 3.29 M. Additionally, the various concentrations of the PFOB phantom imaging revealed quantifiable capacity. Finally, the 1H/19F imaging was implemented with KSSI on one tumor-bearing mouse. This method provides the potential for clinical translation of fluorine probes at low-field MRI systems.

源语言英语
页(从-至)10572-10579
页数8
期刊Analytical Chemistry
95
28
DOI
出版状态已出版 - 18 7月 2023
已对外发布

学术指纹

探究 'High-Sensitivity, Low-Field 19F-MRI Approach Using High Manganese Ferrite Concentrations' 的科研主题。它们共同构成独一无二的指纹。

引用此