跳到主要导航 跳到搜索 跳到主要内容

Heat exchanger network design and economic analysis for coal-fired power plant retrofitted with Co2 capture

  • Cranfield University
  • University of Hull

科研成果: 书/报告/会议事项章节章节同行评审

2 引用 (Scopus)

摘要

Addition of CO2 capture unit to an existing power plant to satisfy environmental regulations has adverse effects on the energy efficiency of the power plant. Heat integration through proper design of heat exchanger network (HEN) remains the most effective way to reduce this energy penalty as well as reducing CO2 emission. Pinch technology remains the most widely used techniques due to its physical insight. This paper aims to present HEN design and economic analysis for power plant retrofitted with post-combustion CO2 capture. The benchmark presented is based on the recent work of Khalilpour and Abbas (2011) (i.e. Ref. [1]). Improvements to Khalilpour and Abbas (2011) include: (1) the use of cost and economic data to evaluate achievable trade-offs between energy, capital and utility cost. This is to determine the optimal minimum temperature difference; (2) redesigning of HEN with the newly determined minimum temperature difference and (3) its comparison with the HEN design presented in Ref. [1]. The results show that the energy penalty imposed on the power plant with CO2 capture plant can be reduced through heat integration of HEN, thus utility cost savings was maximized and the cost of addition of HEN was recovered within a short payback period of about 2.8 years.

源语言英语
主期刊名Computer Aided Chemical Engineering
出版商Elsevier B.V.
433-438
页数6
DOI
出版状态已出版 - 2013
已对外发布

出版系列

姓名Computer Aided Chemical Engineering
32
ISSN(印刷版)1570-7946

联合国可持续发展目标

此成果有助于实现下列可持续发展目标:

  1. 可持续发展目标 7 - 经济适用的清洁能源
    可持续发展目标 7 经济适用的清洁能源

学术指纹

探究 'Heat exchanger network design and economic analysis for coal-fired power plant retrofitted with Co2 capture' 的科研主题。它们共同构成独一无二的指纹。

引用此