He-ICR cleanings were successfully carried out in 2006-2007 on the full superconducting tokamak (EAST), which is an ITER-relevant experimental tokamak. Factors influence on He-ICR efficiency, such as magnetic field, ICRF power and working pressure were investigated. In EAST, the breakdown pressure for He-ICR cleanings could reach 10 Pa. The removal efficiency for H during 20 kW 4.5 × 10-3 Pa He-ICR cleaning was same as that in He-GDC cleaning (2 Pa, 4A). Highest H removal rate in EAST with full metallic material walls, 1.7 × 1022 H/h in 20 kW 3 × 10-2 Pa He-ICR, was higher by a factor of four than that in HT-7 with carbon limiter configuration.
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 207-210 |
| 页数 | 4 |
| 期刊 | Journal of Nuclear Materials |
| 卷 | 376 |
| 期 | 2 |
| DOI | |
| 出版状态 | 已出版 - 31 5月 2008 |