TY - GEN
T1 - General impedance/admittance stability criterion for cascade system
AU - Fangcheng, Liu
AU - Jinjun, Liu
AU - Bin, Zhang
AU - Haodong, Zhang
AU - Ul, Hasan Saad
PY - 2013
Y1 - 2013
N2 - Impedance-based stability criterions have been proved to be a very effective tool for the stability assessment when considering interaction between different modules. Two different stability criterions in the form of impedance ratio as Zo/Zi and Zi/Zo have been proposed for different system. However, the intrinsic relationship of these criterions has not been fully discussed. In this paper, the terminal characteristics of single module are focused. The physical meanings of terminal impedance and admittance are explained. Based on the physical understanding, different mathematical methods are derived for the stability prediction in cascade system. Through comparison, the advantage of proposed impedance/admittance stability criterion is analyzed as its convenience in mathematical calculation. As analyzed, the proposed impedance/admittance criterion can be used in the cascade system where existing impedance ratio type criterion can be used and the physical meaning of proposed criterion is clearer.
AB - Impedance-based stability criterions have been proved to be a very effective tool for the stability assessment when considering interaction between different modules. Two different stability criterions in the form of impedance ratio as Zo/Zi and Zi/Zo have been proposed for different system. However, the intrinsic relationship of these criterions has not been fully discussed. In this paper, the terminal characteristics of single module are focused. The physical meanings of terminal impedance and admittance are explained. Based on the physical understanding, different mathematical methods are derived for the stability prediction in cascade system. Through comparison, the advantage of proposed impedance/admittance stability criterion is analyzed as its convenience in mathematical calculation. As analyzed, the proposed impedance/admittance criterion can be used in the cascade system where existing impedance ratio type criterion can be used and the physical meaning of proposed criterion is clearer.
UR - https://www.scopus.com/pages/publications/84883659634
U2 - 10.1109/ECCE-Asia.2013.6579131
DO - 10.1109/ECCE-Asia.2013.6579131
M3 - 会议稿件
AN - SCOPUS:84883659634
SN - 9781479904822
T3 - 2013 IEEE ECCE Asia Downunder - 5th IEEE Annual International Energy Conversion Congress and Exhibition, IEEE ECCE Asia 2013
SP - 422
EP - 428
BT - 2013 IEEE ECCE Asia Downunder - 5th IEEE Annual International Energy Conversion Congress and Exhibition, IEEE ECCE Asia 2013
T2 - 2013 IEEE ECCE Asia Downunder - 5th IEEE Annual International Energy Conversion Congress and Exhibition, IEEE ECCE Asia 2013
Y2 - 3 June 2013 through 6 June 2013
ER -