摘要
Flashing spray occurs when the saturated liquid is discharged into a gaseous environment at an ambient pressure lower than its saturation pressure. Internal flow is a primary determinant on the behavior of external flashing spray, so its transient effect was investigated with iso-pentane as working medium. The coupled effect of superheat level and injection pressure was comprehensively explored with initial temperature from 30 °C to 70 °C and injection pressure from 1.2 MPa to 2.4 MPa. Under different injection pressure, the stable spray patterns can still be categorized as non-shattering, partially shattering, completely shattering and flare flashing separated by the shattering index X·(Pinj/Pa)0.5 of 0.21, 0.39 and 0.76, which represents the product of homogeneous nucleation rate and the ratio of injection pressure over ambient pressure. A strong correlation between the spray cone angle and the shattering index is proposed as a piecewise function separated by X·(Pinj/Pa)0.5 = 0.39. High-void-fraction internal two-phase flow is easier to be formed in partially shattering or completely shattering pattern, which would lead to a hysteretic flashing spray with a significant increase of spray cone angle and droplets concentration. Low X·(Pinj/Pa)0.5 yields slower response of external morphological changes but larger enhancement of radial expansion.
| 源语言 | 英语 |
|---|---|
| 期刊论文编号 | 126151 |
| 期刊 | Fuel |
| 卷 | 333 |
| DOI | |
| 出版状态 | 已出版 - 1 2月 2023 |
学术指纹
探究 'Flow visualization of the transient effect of the internal two-phase flow on the external iso-pentane flashing spray under different injection pressure' 的科研主题。它们共同构成独一无二的学术指纹。引用此
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver