跳到主要导航 跳到搜索 跳到主要内容

Faster Sensitivity Loss around Dense Scotomas than for Overall Macular Sensitivity in Stargardt Disease: ProgStar Report No. 14

  • ProgStar Study Group
  • Johns Hopkins University
  • Case Western Reserve University
  • Moorfields Eye Hospital NHS Foundation Trust
  • Johannes Kepler University Linz
  • Medical University of Graz
  • Stanford University
  • Retina Foundation of the Southwest
  • University of Pennsylvania
  • Greater Baltimore Medical Center
  • University of California at Los Angeles
  • Institute of Molecular and Clinical Ophthalmology Basel
  • University of Basel

科研成果: 期刊稿件 › 文章 › 同行评审

29 引用 (Scopus)

摘要

Purpose: Mean sensitivity (MS) derived from a standard test grid using microperimetry is a sensitive outcome measure in clinical trials investigating new treatments for degenerative retinal diseases. This study hypothesizes that the functional decline is faster at the edge of the dense scotoma (eMS) than by using the overall MS. Design: Multicenter, international, prospective cohort study: ProgStar Study. Methods: Stargardt disease type 1 patients (carrying at least 1 mutation in the ABCA4 gene) were followed over 12 months using microperimetry with a Humphrey 10-2 test grid. Customized software was developed to automatically define and selectively follow the test points directly adjacent to the dense scotoma points and to calculate their mean sensitivity (eMS). Results: Among 361 eyes (185 patients), the mean age was 32.9 ± 15.1 years old. At baseline, MS was 10.4 ± 5.2 dB (n = 361), and the eMS was 9.3 ± 3.3 dB (n = 335). The yearly progression rate of MS (1.5 ± 2.1 dB/year) was significantly lower (β = −1.33; P < .001) than that for eMS (2.9 ± 2.9 dB/year). There were no differences between progression rates using automated grading and those using manual grading (β = .09; P = .461). Conclusions: In Stargardt disease type 1, macular sensitivity declines significantly faster at the edge of the dense scotoma than in the overall test grid. An automated, time-efficient approach for extracting and grading eMS is possible and appears valid. Thus, eMS offers a valuable tool and sensitive outcome parameter with which to follow Stargardt patients in clinical trials, allowing clinical trial designs with shorter duration and/or smaller cohorts.

源语言英语
页(从-至)219-225
页数7
期刊American Journal of Ophthalmology
卷216
DOI
出版状态已出版 - 8月 2020

学术指纹

探究 'Faster Sensitivity Loss around Dense Scotomas than for Overall Macular Sensitivity in Stargardt Disease: ProgStar Report No. 14' 的科研主题。它们共同构成独一无二的学术指纹。

引用此