跳到主要导航 跳到搜索 跳到主要内容

Experimental study on the performance of an aircraft environmental control system

  • Hongli Zhao
  • , Yu Hou
  • , Yongfeng Zhu
  • , Liang Chen
  • , Shuangtao Chen
  • Xi'an Jiaotong University
  • The First Aircraft Institute

科研成果: 期刊稿件 › 文章 › 同行评审

77 引用 (Scopus)

摘要

In this paper, the experimental study on the off-design performance and dynamic response of an aircraft environmental control system (ECS) was presented. A bootstrap air cycle refrigeration system with high-pressure water separation was employed in the ECS. Both the static test and the dynamic test were conducted on the ECS. The performance of the key components including precooler, recuperator, compressor, and turbine was investigated. The test results show the performance of the tested ECS can meet the requirements of design. However, some parameters including outlet pressure, turbine efficiency, and rotational speed might vary obviously when the operation conditions changed. The outlet humidity ratio and outlet temperature might also fluctuate largely during the start-up process. It is necessary to take into account the off-design performance and the transient performance in the design of ECS.

源语言英语
页(从-至)3284-3288
页数5
期刊Applied Thermal Engineering
卷29
期16
DOI
出版状态已出版 - 11月 2009

学术指纹

探究 'Experimental study on the performance of an aircraft environmental control system' 的科研主题。它们共同构成独一无二的学术指纹。

引用此