Experimental study on cryogenic counterflow woven-wire screen matrix heat exchanger

  • Shuangtao Chen
  • , Hongli Zhao
  • , Yu Hou
  • , Qiaoyu Zhang
  • Xi'an Jiaotong University

科研成果: 期刊稿件文章同行评审

3 引用 (Scopus)

摘要

This paper presents an experimental study of two recuperative-type counterflow woven-wire screen matrix heat exchangers that have the same cross-sectional geometric parameters and different lengths. Parts of thermal parameters and flow parameters of the longer heat exchanger (unit A) and the shorter heat exchanger (unit B) were compared in a temperature range of 100-300 K. The results show that, with a longer-length, unit A has the higher overall exergetic effectiveness and the larger pressure drop in the range of flowrate tested. Moreover, a heat-rate load of 293Wwith an overall exergetic effectiveness of 85% was achieved by unit A when the mass flow rate was 1.5 g/s.

源语言英语
页(从-至)322-327
页数6
期刊Journal of Thermophysics and Heat Transfer
26
2
DOI
出版状态已出版 - 2012