摘要
An investigation of the characteristics of flowrate transients within slug flow was conducted in a large scale outdoor testing facility. The test section consisted of a 378 m long, 7.62 cm diameter stainless steel pipe. Air and water were used as the test fluids. The response to a change of flowrate of either phase of two phases was measured using a series of pressure transducers and differential pressure transducers. An increase or decease in the gas flowrate caused a pressure overshoot above the value at a new steady state or led to a pressure undershoot to form a temporary stratified flow. Pressure waves existed in the pipeline, spreading from the entrance to the exit. The magnitude of pressure overshoot in up-gas transient or of pressure undershoot the and period of the temporary stratified flow in down-gas transient are related to the change of gas flowrate and the distance away from the entrance. In contrast, the change in liquid flowrate was accommodated by smooth transitions between the corresponding steady states, and only one obvious change was found in the slug frequency. According to experimental results, the pressure overshoot, the pressure undershoot and the pressure wave propagation were analyzed, and the phenomena were explained reasonably. Some correlations for the calculation of the pressure overshoot and undershoot were proposed.
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 396-403 |
| 页数 | 8 |
| 期刊 | Chinese Journal of Chemical Engineering |
| 卷 | 10 |
| 期 | 4 |
| 出版状态 | 已出版 - 8月 2002 |