跳到主要导航 跳到搜索 跳到主要内容

Experimental research on medical wastewater disposal by supercritical water oxidation

  • Xi'an Jiaotong University

科研成果: 期刊稿件 › 文章 › 同行评审

3 引用 (Scopus)

摘要

The oxidation of medical wastewater in supercritical water was investigated experimentally in a batch reactor. The results show that the COD removal rate of medical wastewater obviously increases with the increases of reaction time and temperature rise; whereas it scarcely changes with pressure in the range of 25-27 MPa. Both MnSO4 and CuSO4 are active catalysts for COD removal rate of the wastewater, and CuSO4 offers greater influence when reaction time is less than 7 min. Ammonia-nitrogen mass concentration has no evident variation under various reaction conditions. The experimental data under the conditions of 420-480°C, 25 MPa, and oxidant stoichiometric ratio 300% were used to fit the rate of reaction in a non-linear regression analysis, with the parameter values determined as follows: activation energy (170.025±11.692)kJ/mol, pre-exponential factor (4.98±0.01)×108 min-1·mg-0.918·L0.918 and reaction order of wastewater (based on COD) 1.918±0.256, and the confidence level of such kinetics modeling is 93%. Based on the enthalpy changes of the reaction mediums, the reaction heat of the medical wastewater in supercritical water oxidation (SCWO) was studied. The results indicate that the reaction heat is 296.63 kJ/kg when the organics are completely oxidized.

源语言英语
页(从-至)12-16
页数5
期刊Huaxue Gongcheng/Chemical Engineering (China)
卷39
期4
出版状态已出版 - 4月 2011

学术指纹

探究 'Experimental research on medical wastewater disposal by supercritical water oxidation' 的科研主题。它们共同构成独一无二的学术指纹。

引用此