摘要
This paper presents an experimental research on configuration optimization of a frost-free refrigerator-freezer with the parallel circuit cycle based on the analysis of circuit switching characteristics. Through combination optimization of R-fan voltage, F-fan voltage, R-capillary tube flow capacity, refrigerant charge, structure of suction pipe, F-compressor speed and R-compressor speed, the system could save 9.27% energy consumption compared with the initial condition. The experimental results also showed that the larger the R-capillary tube flow capacity, the larger the flow rate of the RC, resulting in the quickly temperature drop in R-cabinet and slowly temperature drop in R-cabinet based on “R-cabinet temperature priority” control strategy. Additionally, the R-cabinet temperature drop rate decreased with the increase of ambient temperature but the F-cabinet temperature drop rate was almost unaffected by the ambient temperature.
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 415-426 |
| 页数 | 12 |
| 期刊 | International Journal of Refrigeration |
| 卷 | 118 |
| DOI | |
| 出版状态 | 已出版 - 10月 2020 |
联合国可持续发展目标
此成果有助于实现下列可持续发展目标:
-
可持续发展目标 7 经济适用的清洁能源
学术指纹