摘要
With the T-junction formed by the fourth stage automatic depressurization system (ADS-4) and hot leg in AP1000 nuclear power plant as object of study, a small-scale experiment research on entrainment at T-junction was performed. The visualization research indicates that the entrainment phenomena through a large size branch are apparently different from those through a small branch. Two entrainment mechanisms could be found in the stratified flow entrainment area. Intermittent flow entrainment tends to occur at a lower Froude number and a lower gas chamber height. Annular flow entrainment always arises at a higher Froude number. Also, the experimental research shows that the reverse flow is observable in a large size branch inlet. The geometry of the branch has an important effect on the onset entrainment. In addition, liquid crossflow does not seem to affect the onset entrainment.
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 807-812 |
| 页数 | 6 |
| 期刊 | Yuanzineng Kexue Jishu/Atomic Energy Science and Technology |
| 卷 | 49 |
| 期 | 5 |
| DOI | |
| 出版状态 | 已出版 - 20 5月 2015 |
学术指纹