TY - JOUR
T1 - Experimental investigation to natural convective heat transfer in wire-woven bulk Kagome truss
AU - Yang, Xiaohu
AU - Bai, Jiaxi
AU - Lu, Tianjian
AU - Kim, Tongbeum
AU - Kang, Ki Ju
PY - 2014/7
Y1 - 2014/7
N2 - Natural convection on a novel periodic lattice frame material wire-woven bulk Kagome-sintered plate (WBK) at different inclination angles is experimentally investigated, and overall heat transfer performance is evaluated by the total thermal resistance concerning the effects of orientations (o-a, o-b, and o-c) and inclination angles covering 0° (horizontal orientation), 15°, 30°, 45°, 60°, 75°, and 90° (vertical orientation). The optimal inclination angle is found to approach 50°, corresponding to the minimum thermal resistance at a heat flux of 1150 W/m2. The average thermal resistance for WBK specimens gets 42% that of the smooth plate in the Rayleigh number range of 6.1×107-2.2×108. The heat transfer performance (thermal resistance) of WBK sample is different in three orientations due to its strong anisotropic topology: o-b orientation has smallest thermal resistance, but o-a orientation has the biggest one. Moderate blockage ratio results in relatively high flow mixing but acceptable flow resistance, ultimately leading to enhancing natural convective heat transfer.
AB - Natural convection on a novel periodic lattice frame material wire-woven bulk Kagome-sintered plate (WBK) at different inclination angles is experimentally investigated, and overall heat transfer performance is evaluated by the total thermal resistance concerning the effects of orientations (o-a, o-b, and o-c) and inclination angles covering 0° (horizontal orientation), 15°, 30°, 45°, 60°, 75°, and 90° (vertical orientation). The optimal inclination angle is found to approach 50°, corresponding to the minimum thermal resistance at a heat flux of 1150 W/m2. The average thermal resistance for WBK specimens gets 42% that of the smooth plate in the Rayleigh number range of 6.1×107-2.2×108. The heat transfer performance (thermal resistance) of WBK sample is different in three orientations due to its strong anisotropic topology: o-b orientation has smallest thermal resistance, but o-a orientation has the biggest one. Moderate blockage ratio results in relatively high flow mixing but acceptable flow resistance, ultimately leading to enhancing natural convective heat transfer.
KW - Anisotropy
KW - Inclination angle
KW - Natural convection
KW - Wire-woven bulk Kagome
UR - https://www.scopus.com/pages/publications/84904900468
U2 - 10.7652/xjtuxb201407003
DO - 10.7652/xjtuxb201407003
M3 - 文章
AN - SCOPUS:84904900468
SN - 0253-987X
VL - 48
SP - 12
EP - 16
JO - Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University
JF - Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University
IS - 7
ER -