跳到主要导航 跳到搜索 跳到主要内容

Experimental investigation on two-phase driven ejector performance in a novel ejector enhanced refrigeration system

科研成果: 期刊稿件文章同行评审

59 引用 (Scopus)

摘要

This paper presents an experimental investigation on two-phase driven ejector performance characteristics in a novel ejector enhanced refrigeration system (NERC). An experimental setup using refrigerant R600a is designed and built based on the NERC system. In the experimental setup, the ejector uses two-phase refrigerant coming from the high-temperature evaporator as the primary fluid. The experiments are carried out to examine the influences of the main operational and geometric parameters, including the primary fluid pressure, the secondary fluid pressure, the NXP and the nozzle throat diameter. The results show that the entrainment ratio, the pressure lift ratio and the overall ejector efficiency of the two-phase driven ejector are strongly affected by those parameters. Additionally, the effect of the quality of the two-phase primary fluid is also experimentally investigated. The meaningful results obtained here may serve as good guidelines for further improving the two-phase driven ejector performance and providing promising use of the two-phase driven ejector in the ejector-expansion technology.

源语言英语
页(从-至)391-400
页数10
期刊Energy Conversion and Management
111
DOI
出版状态已出版 - 1 3月 2016

联合国可持续发展目标

此成果有助于实现下列可持续发展目标:

  1. 可持续发展目标 7 - 经济适用的清洁能源
    可持续发展目标 7 经济适用的清洁能源

学术指纹

探究 'Experimental investigation on two-phase driven ejector performance in a novel ejector enhanced refrigeration system' 的科研主题。它们共同构成独一无二的指纹。

引用此