跳到主要导航 跳到搜索 跳到主要内容

Experimental investigation on flow rate of boil-off gas compressor at low suction temperature

  • Xi'an Jiaotong University

科研成果: 期刊稿件文章同行评审

1 引用 (Scopus)

摘要

The low suction temperature has a significant effect on the volumetric efficiency of BOG (boil-off gas) compressors. A test rig with temperature sensors was built up to investigate the temperature distribution in the cylinder at various suction temperatures. The suction and discharge flow rates were both measured by the volume flow meter. The heating tape on the pipe before the compressor inlet and the by-pass line were used to adjust the suction temperature. From the test data, the main factors influencing the volumetric efficiency were analyzed, focusing on the temperature coefficient and the suction coefficient. The results show that the suction coefficient, temperature coefficient and volumetric coefficient decreased by 24.4%, 25%, and 23.75%, respectively, when the suction temperature decreased from -54.2°C to -142.2°C. The temperature difference on the cylinder outer surface reached the maximum, 76°C, at the suction temperature of -142.2°C.

源语言英语
页(从-至)68-71+127
期刊Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University
48
3
DOI
出版状态已出版 - 2014

学术指纹

探究 'Experimental investigation on flow rate of boil-off gas compressor at low suction temperature' 的科研主题。它们共同构成独一无二的学术指纹。

引用此