跳到主要导航 跳到搜索 跳到主要内容

Experimental investigation on flashing duration time

  • Xi'an Jiaotong University

科研成果: 期刊稿件文章同行评审

5 引用 (Scopus)

摘要

An experimental study has been performed to investigate pool water instantaneous flash evaporation in a rectangle chamber. Some key parameters such as superheat, initial water temperature and water level have been studied. The water level was at 40 mm, 60 mm, 100 mm, 150 mm. Initial conditions of the liquid varied from 36°C to 88°C temperature and 2.1°C to 48°C superheat. The experimental results showed that the initial water temperature, the superheat and the water level are the key parameters. The experimental results showed that the greater the superheat and the higher the initial water level approaches, the longer the flashing will persist. Under a constant superheat, the initial water temperature has little influence on duration of flashing. Experimental study allows us to correlate the flashing duration time with the superheat and the initial water level as well as the initial water temperature.

源语言英语
页(从-至)1339-1342
页数4
期刊Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics
30
8
出版状态已出版 - 8月 2009

学术指纹

探究 'Experimental investigation on flashing duration time' 的科研主题。它们共同构成独一无二的学术指纹。

引用此