摘要
An experimental investigation is described for the characteristics of convective boiling flow instabilities in horizontally helically coiled tubes using a steam-water two-phase closed circulation test loop at pressure from 0.5 MPa to 3.5 MPa. Three kinds of oscillation are reported: density waves; pressure drop excursions; thermal fluctuations. We describe their dependence on main system parameters such as system pressure, mass flowrate inlet subcooling, compressible volume and heat flux. Utilising the experimental data together with conservation constraints, a dimensionless correlation is proposed for the occurrence of density waves.
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 210-216 |
| 页数 | 7 |
| 期刊 | Journal of Thermal Science |
| 卷 | 5 |
| 期 | 3 |
| DOI | |
| 出版状态 | 已出版 - 7月 1996 |
学术指纹
探究 'Experimental investigation of forced convective boiling flow instabilities in horizontal helically coiled tubes' 的科研主题。它们共同构成独一无二的学术指纹。引用此
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver