摘要
The stall inception of a single low speed compressor was investigated with uniform inlet flow. By installing high response dynamic pressure transducers in the circumferential and axial directions, the dynamic pressure data at different positions were collected and analyzed using time analysis and frequency analysis, respectively. The results indicate that the spike-type inception will appear before stall; the stall cells are splited and incorporated, but two cells are always incorporated to one when exiting from stalling quickly; and frequency analysis of the dynamic pressure validate the veracity of the number of stall cell.
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 426-431 |
| 页数 | 6 |
| 期刊 | Hangkong Dongli Xuebao/Journal of Aerospace Power |
| 卷 | 28 |
| 期 | 2 |
| 出版状态 | 已出版 - 2月 2013 |
| 已对外发布 | 是 |
学术指纹
探究 'Experiment on single axial compressor of characteristic of rotating stall' 的科研主题。它们共同构成独一无二的学术指纹。引用此
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver