TY - JOUR
T1 - Exergo-economic analysis for screening of metal hydride pairs for thermochemical energy storage for solar baking system
AU - Ayub, Iqra
AU - Nasir, Muhammad Salman
AU - Liu, Yang
AU - Munir, Anjum
AU - Wu, Zhen
AU - Yang, Fusheng
AU - Zhang, Zaoxiao
N1 - Publisher Copyright:
© 2022 Elsevier Ltd
PY - 2022/5/1
Y1 - 2022/5/1
N2 - The novelty of this research work is the exergo-economic analysis (including the cost of exergy destruction and exergy loss) of metal hydride based thermal energy storage system coupled with a solar bakery unit for the screening of metal hydride pairs (Case 1: pure MgH2/LaNi5 & Case 2: V2O5 doped MgH2/LaNi5) for thermochemical energy storage. Firstly, a numerical simulation is performed by using COMSOL Multiphysics 5.3a software. Secondly, an economic and exergo-economic model is developed to calculate the annual levelized cost of the thermal energy storage system. The life-cycle economic assessment findings indicate that the Levelized thermal energy storage cost of the pure MgH2 based system (32.28 $ /kWhth) is 8.2 times higher than that of the V2O5 doped MgH2 system (3.954 $/kWhth). Moreover, an 87.75% decrease in cost was observed in Case 2 (V2O5 doped MgH2). Furthermore, Case 2 (V2O5 doped MgH2) can save 92.58 % of hydrogenation reaction time as compared to Case 1 (Pure MgH2). Ultimately, the selection of V2O5 based MgH2 as a thermal heat-storing medium is then assessed as a better option for the MHTES for the solar bakery unit (SBU). The findings of this research provide a clear insight into the mechanism of cost formation in the system.
AB - The novelty of this research work is the exergo-economic analysis (including the cost of exergy destruction and exergy loss) of metal hydride based thermal energy storage system coupled with a solar bakery unit for the screening of metal hydride pairs (Case 1: pure MgH2/LaNi5 & Case 2: V2O5 doped MgH2/LaNi5) for thermochemical energy storage. Firstly, a numerical simulation is performed by using COMSOL Multiphysics 5.3a software. Secondly, an economic and exergo-economic model is developed to calculate the annual levelized cost of the thermal energy storage system. The life-cycle economic assessment findings indicate that the Levelized thermal energy storage cost of the pure MgH2 based system (32.28 $ /kWhth) is 8.2 times higher than that of the V2O5 doped MgH2 system (3.954 $/kWhth). Moreover, an 87.75% decrease in cost was observed in Case 2 (V2O5 doped MgH2). Furthermore, Case 2 (V2O5 doped MgH2) can save 92.58 % of hydrogenation reaction time as compared to Case 1 (Pure MgH2). Ultimately, the selection of V2O5 based MgH2 as a thermal heat-storing medium is then assessed as a better option for the MHTES for the solar bakery unit (SBU). The findings of this research provide a clear insight into the mechanism of cost formation in the system.
KW - Annual levelized cost of the thermal energy storage system
KW - Exergo-economic analysis
KW - Exergy destruction and loss cost
KW - Metal hydride based thermal energy storage
KW - Screening of metal hydride pair
UR - https://www.scopus.com/pages/publications/85126602471
U2 - 10.1016/j.tsep.2022.101271
DO - 10.1016/j.tsep.2022.101271
M3 - 文章
AN - SCOPUS:85126602471
SN - 2451-9049
VL - 30
JO - Thermal Science and Engineering Progress
JF - Thermal Science and Engineering Progress
M1 - 101271
ER -