N2 - Most ultrasonic guided wave methods focus on tone burst excitation to reduce the effect of dispersion so as to facilitate signal interpretation. However, the resolution of the output cannot attain a very high value because time duration of the excitation waveform cannot be very small. To overcome this limitation, a pulse compression technique is introduced to Lamb wave propagation to achieve a d-like correlation so as to obtain a high resolution for inspection. Ideal d-like correlation is impossible as only a finite frequency bandwidth can propagate. The primary purpose of this paper is to design a proper excitation waveform for Lamb wave pulse compression, which shortens the correlation as close as possible to a d function. To achieve this purpose, the performance of some typical signals is discussed in pulse compression, which include linear chirp (L-Chirp) signal, nonlinear chirp (NLChirp) signal, Barker code (BC), and Golay complementary code (GCC). In addition, how the excitation frequency range influences inspection resolution is investigated. A strategy for the frequency range determination is established subsequently. Finally, an experiment is carried out on an aluminum plate where these typical signals are used as excitations at different frequency ranges. The quantitative comparisons of the pulse compression responses validate the theoretical findings. By utilizing the experimental data, the improvement of pulse compression in resolution compared with tone burst excitation is also validated, and the robustness of the waveform design method to inaccuracies in the dispersion compensation is discussed as well.
AB - Most ultrasonic guided wave methods focus on tone burst excitation to reduce the effect of dispersion so as to facilitate signal interpretation. However, the resolution of the output cannot attain a very high value because time duration of the excitation waveform cannot be very small. To overcome this limitation, a pulse compression technique is introduced to Lamb wave propagation to achieve a d-like correlation so as to obtain a high resolution for inspection. Ideal d-like correlation is impossible as only a finite frequency bandwidth can propagate. The primary purpose of this paper is to design a proper excitation waveform for Lamb wave pulse compression, which shortens the correlation as close as possible to a d function. To achieve this purpose, the performance of some typical signals is discussed in pulse compression, which include linear chirp (L-Chirp) signal, nonlinear chirp (NLChirp) signal, Barker code (BC), and Golay complementary code (GCC). In addition, how the excitation frequency range influences inspection resolution is investigated. A strategy for the frequency range determination is established subsequently. Finally, an experiment is carried out on an aluminum plate where these typical signals are used as excitations at different frequency ranges. The quantitative comparisons of the pulse compression responses validate the theoretical findings. By utilizing the experimental data, the improvement of pulse compression in resolution compared with tone burst excitation is also validated, and the robustness of the waveform design method to inaccuracies in the dispersion compensation is discussed as well.
KW - Frequency range determination
KW - Lamb waves
KW - Pulse compression
KW - Waveform design
UR - https://www.scopus.com/pages/publications/85009508780
U2 - 10.1109/TUFFC.2015.2496292
DO - 10.1109/TUFFC.2015.2496292
M3 - 文献综述
AN - SCOPUS:85009508780
SN - 0885-3010
VL - 63
SP - 165
EP - 177
JO - IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
JF - IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
IS - 1
M1 - 7322292
ER -