TY - JOUR
T1 - Evaluation of accuracy of automatic out-of-plane respiratory gating for DCEUS-based quantification using principal component analysis
AU - Wang, Diya
AU - Su, Zhe
AU - Su, Qiang
AU - Zhang, Xinyu
AU - Qu, Zhen
AU - Wang, Na
AU - Zong, Yujin
AU - Yang, Yaning
AU - Wan, Mingxi
N1 - Publisher Copyright:
© 2018 Elsevier Ltd
PY - 2018/12
Y1 - 2018/12
N2 - The accuracy of abdominal multi-parametric quantification based on dynamic contrast-enhanced ultrasound (DCEUS) is limited by out-of-plane severe distortion induced by respiratory motion. This study developed a fully automatic respiratory gating scheme by using principal component analysis to remove distortions and disturbances in free-breathing DCEUS-based quantification. Taking the known in-vitro perfusions as ground truths, we further evaluated the respiratory gating accuracy from multiple perspectives in a controllable rotary distortion flow model with out-of-plane severe distortion induced by respiratory motion. Compared with those without respiratory gating, the signal-to-clutter ratio and correlation coefficients of perfusion parameters with respiratory gating improved by 3.99 ± 1.71 dB (p < 0.01) and 0.39 ± 0.17 (p < 0.01), respectively. The corresponding mean square error decreased by 1893.9 ± 763.16 (p < 0.001). Results with respiratory gating were significantly consistent with the ground truths without respiratory motion disturbances. Quantitative results demonstrated the effective removal of out-of-plane serious distortion and other disturbances induced by the respiratory kinetics on DCEUS-based quantification. The accuracy and robustness of DCEUS-based quantification were significantly improved by the proposed respiratory gating strategy, which not only benefits physicians in identifying transient hemodynamic characteristics in tumor angiogenesis, but also provides accurate diagnoses for abdominal tumors.
AB - The accuracy of abdominal multi-parametric quantification based on dynamic contrast-enhanced ultrasound (DCEUS) is limited by out-of-plane severe distortion induced by respiratory motion. This study developed a fully automatic respiratory gating scheme by using principal component analysis to remove distortions and disturbances in free-breathing DCEUS-based quantification. Taking the known in-vitro perfusions as ground truths, we further evaluated the respiratory gating accuracy from multiple perspectives in a controllable rotary distortion flow model with out-of-plane severe distortion induced by respiratory motion. Compared with those without respiratory gating, the signal-to-clutter ratio and correlation coefficients of perfusion parameters with respiratory gating improved by 3.99 ± 1.71 dB (p < 0.01) and 0.39 ± 0.17 (p < 0.01), respectively. The corresponding mean square error decreased by 1893.9 ± 763.16 (p < 0.001). Results with respiratory gating were significantly consistent with the ground truths without respiratory motion disturbances. Quantitative results demonstrated the effective removal of out-of-plane serious distortion and other disturbances induced by the respiratory kinetics on DCEUS-based quantification. The accuracy and robustness of DCEUS-based quantification were significantly improved by the proposed respiratory gating strategy, which not only benefits physicians in identifying transient hemodynamic characteristics in tumor angiogenesis, but also provides accurate diagnoses for abdominal tumors.
KW - Contrast-enhanced ultrasound
KW - Principal component analysis
KW - Quantification
KW - Respiratory kinetics
UR - https://www.scopus.com/pages/publications/85055735374
U2 - 10.1016/j.compmedimag.2018.10.004
DO - 10.1016/j.compmedimag.2018.10.004
M3 - 文章
C2 - 30390573
AN - SCOPUS:85055735374
SN - 0895-6111
VL - 70
SP - 155
EP - 164
JO - Computerized Medical Imaging and Graphics
JF - Computerized Medical Imaging and Graphics
ER -