TY - JOUR
T1 - Estimation of postmortem interval in rat liver and spleen using Fourier transform infrared spectroscopy
AU - Huang, Ping
AU - Tian, Weiping
AU - Tuo, Ya
AU - Wang, Zhenyuan
AU - Yang, Guangde
PY - 2009/3
Y1 - 2009/3
N2 - The aim of this study was to investigate the changes of Fourier transform infrared (FT-IR) spectra of rat liver and spleen tissues from time zero to 144 h postmortem. The absorbance (Ax represents the infrared absorbance at wavenumber x cm-1) ratios of major absorbance bands were examined. A3303/A2925, A1647/A1541 (liver), A1238/A1338, A1153/A1338 (liver), A1080/A1338, and A1030-1050/A1338 (liver) showed a decrease postmortem, whereas the A1396/A1456 ratio (spleen) showed an increase. Furthermore, these absorbance ratios showed a strong linear relationship with increasing time postmortem, and the A1238/A1338 ratio of spleen offered a stronger correlation (R2 = 0.88) than did the others. A new absorbance band appeared at 1120 cm-1 for the liver and spleen at 120 h postmortem and another new band appeared at 1170 cm-1 for the liver, but the existing absorbance band at 1170 cm-1 disappeared in the spleen. Our initial results demonstrate that the quantitative analysis of FT-IR spectrum related to postmortem interval (PMI) shows a strong linear correlation between absorbance ratios and increasing time after death. The FT-IR changes of spectra and absorbance ratios can support further study for estimating short-term and long-term PMI. Upon future validation, FT-IR can offer advantages in combination with established methods to improve PMI estimation.
AB - The aim of this study was to investigate the changes of Fourier transform infrared (FT-IR) spectra of rat liver and spleen tissues from time zero to 144 h postmortem. The absorbance (Ax represents the infrared absorbance at wavenumber x cm-1) ratios of major absorbance bands were examined. A3303/A2925, A1647/A1541 (liver), A1238/A1338, A1153/A1338 (liver), A1080/A1338, and A1030-1050/A1338 (liver) showed a decrease postmortem, whereas the A1396/A1456 ratio (spleen) showed an increase. Furthermore, these absorbance ratios showed a strong linear relationship with increasing time postmortem, and the A1238/A1338 ratio of spleen offered a stronger correlation (R2 = 0.88) than did the others. A new absorbance band appeared at 1120 cm-1 for the liver and spleen at 120 h postmortem and another new band appeared at 1170 cm-1 for the liver, but the existing absorbance band at 1170 cm-1 disappeared in the spleen. Our initial results demonstrate that the quantitative analysis of FT-IR spectrum related to postmortem interval (PMI) shows a strong linear correlation between absorbance ratios and increasing time after death. The FT-IR changes of spectra and absorbance ratios can support further study for estimating short-term and long-term PMI. Upon future validation, FT-IR can offer advantages in combination with established methods to improve PMI estimation.
KW - Fourier transform infrared spectroscopy
KW - Liver
KW - Postmortem interval
KW - Spleen
UR - https://www.scopus.com/pages/publications/61649083551
U2 - 10.1080/00387010802375362
DO - 10.1080/00387010802375362
M3 - 文章
AN - SCOPUS:61649083551
SN - 0038-7010
VL - 42
SP - 108
EP - 116
JO - Spectroscopy Letters
JF - Spectroscopy Letters
IS - 2
ER -