TY - JOUR
T1 - Epicardial ablation of right pulmonary artery ganglionated plexi for the prevention of atrial fibrillation originating in the pulmonary veins
AU - Wang, Hongtao
AU - Li, Jun
AU - Hong, Changming
AU - Liu, Xiongtao
AU - Shang, Fujun
AU - He, Yong
AU - Wang, Zikuan
AU - Zheng, Qiangsun
PY - 2010/7
Y1 - 2010/7
N2 - Problem Presented: A novel study of catheter ablation of the right pulmonary artery ganglionated plexi (RPA GP) to reduce atrial fibrillation (AF) originating in the pulmonary veins (PVs) is presented. Studies Undertaken: In 20 dogs, atrial effective refractory periods (AERPs), PVERP, and the dispersion of AERP (dAERP) were measured at baseline during RPA GP stimulation and after ablation. Programmed stimulation and burst stimulation protocols were performed at 4 distal PVs to measure the percentage of AF induced before and after ablation. Results: Stimulation of the RPA GP shortened AERP (116 ± 16 vs 130 ± 10 milliseconds, P < .01) and PVERP (122 ± 14 vs 136 ± 12 milliseconds, P < .01), and increased dAERP (31 ± 6 vs 23 ± 6 milliseconds, P < .01). However, the above indices revealed an adverse change after excision (AERP, 138 ± 7 vs 130 ± 10 milliseconds; PVERP, 146 ± 18 vs 136 ± 12 milliseconds; and dAERP, 19 ± 5 vs 23 ± 6 milliseconds; P < .05). Furthermore, the percentage of AF induced from PVs was significantly reduced with vagosympathetic stimulation (40% vs 90%, P < .01). Conclusions: Ablation of the RPA GP changes the electrophysiologic properties of both the atria and the PVs and decreases AF inducibility arising from the PVs.
AB - Problem Presented: A novel study of catheter ablation of the right pulmonary artery ganglionated plexi (RPA GP) to reduce atrial fibrillation (AF) originating in the pulmonary veins (PVs) is presented. Studies Undertaken: In 20 dogs, atrial effective refractory periods (AERPs), PVERP, and the dispersion of AERP (dAERP) were measured at baseline during RPA GP stimulation and after ablation. Programmed stimulation and burst stimulation protocols were performed at 4 distal PVs to measure the percentage of AF induced before and after ablation. Results: Stimulation of the RPA GP shortened AERP (116 ± 16 vs 130 ± 10 milliseconds, P < .01) and PVERP (122 ± 14 vs 136 ± 12 milliseconds, P < .01), and increased dAERP (31 ± 6 vs 23 ± 6 milliseconds, P < .01). However, the above indices revealed an adverse change after excision (AERP, 138 ± 7 vs 130 ± 10 milliseconds; PVERP, 146 ± 18 vs 136 ± 12 milliseconds; and dAERP, 19 ± 5 vs 23 ± 6 milliseconds; P < .05). Furthermore, the percentage of AF induced from PVs was significantly reduced with vagosympathetic stimulation (40% vs 90%, P < .01). Conclusions: Ablation of the RPA GP changes the electrophysiologic properties of both the atria and the PVs and decreases AF inducibility arising from the PVs.
KW - Ablation
KW - Atrial fibrillation
KW - Pulmonary vein
KW - The right pulmonary artery ganglionated plexi
KW - Vagosympathetic nerve
UR - https://www.scopus.com/pages/publications/77953583615
U2 - 10.1016/j.jelectrocard.2010.03.007
DO - 10.1016/j.jelectrocard.2010.03.007
M3 - 文章
C2 - 20580770
AN - SCOPUS:77953583615
SN - 0022-0736
VL - 43
SP - 367
EP - 372
JO - Journal of Electrocardiology
JF - Journal of Electrocardiology
IS - 4
ER -