TY - JOUR
T1 - Enzyme-accelerated catalytic DNA circuits enable rapid and one-pot detection of bacterial pathogens
AU - Li, Baolin
AU - Jiang, Hui
AU - Luo, Sijian
AU - Zeng, Zhangrui
AU - Xu, Xuejing
AU - Li, Xinyu
AU - Zhang, Songzhi
AU - Chen, Yirong
AU - Ding, Shijia
AU - Li, Xinmin
AU - Liu, Jinbo
AU - Chen, Wei
N1 - Publisher Copyright:
© 2024 Elsevier B.V.
PY - 2025/1/1
Y1 - 2025/1/1
N2 - Catalytic DNA circuits, serving as signal amplification strategies, can enable simple and accurate detection of pathogenic bacteria in complex matrices but suffer from low reaction rates and depths. Herein, we design an enzyme-accelerated catalytic hairpin assembly (EACHA) in which duplex DNA products are converted into hairpin reactants to continue participating in the next circuit reaction with the assistance of RNase H. Profiting from the high recyclability of the reactants, EACHA exhibits an approximately 37.6-fold enhancement in the rate constant and a two-order-of-magnitude improvement in sensitivity compared to conventional catalytic hairpin assembly (CHA). By integrating an allosteric probe with EACHA, a one-pot method is developed for rapid and direct detection of S. enterica Enteritidis (S. Enteritidis). This method is capable of detecting 15 CFU mL−1 of S. Enteritidis within 20 min, which is superior to that of real-time PCR. By testing 60 milk samples, we demonstrate this method's high accuracy in discriminating contaminated samples, with an area under the curve (AUC) of 0.997. Moreover, this method can be employed to accurately diagnose early-stage infected mice, with an AUC of 1.00 for feces samples and 0.986 for serum samples. Therefore, this study offers a simple and feasible method for identifying pathogens in complex matrices.
AB - Catalytic DNA circuits, serving as signal amplification strategies, can enable simple and accurate detection of pathogenic bacteria in complex matrices but suffer from low reaction rates and depths. Herein, we design an enzyme-accelerated catalytic hairpin assembly (EACHA) in which duplex DNA products are converted into hairpin reactants to continue participating in the next circuit reaction with the assistance of RNase H. Profiting from the high recyclability of the reactants, EACHA exhibits an approximately 37.6-fold enhancement in the rate constant and a two-order-of-magnitude improvement in sensitivity compared to conventional catalytic hairpin assembly (CHA). By integrating an allosteric probe with EACHA, a one-pot method is developed for rapid and direct detection of S. enterica Enteritidis (S. Enteritidis). This method is capable of detecting 15 CFU mL−1 of S. Enteritidis within 20 min, which is superior to that of real-time PCR. By testing 60 milk samples, we demonstrate this method's high accuracy in discriminating contaminated samples, with an area under the curve (AUC) of 0.997. Moreover, this method can be employed to accurately diagnose early-stage infected mice, with an AUC of 1.00 for feces samples and 0.986 for serum samples. Therefore, this study offers a simple and feasible method for identifying pathogens in complex matrices.
KW - Bacterial pathogen detection
KW - Diagnosis of infection
KW - Enzyme-accelerated catalyst hairpin assembly
KW - Rapid and one-pot assay
KW - Reaction rate and depth
UR - https://www.scopus.com/pages/publications/85205322321
U2 - 10.1016/j.bios.2024.116822
DO - 10.1016/j.bios.2024.116822
M3 - 文章
C2 - 39362139
AN - SCOPUS:85205322321
SN - 0956-5663
VL - 267
JO - Biosensors and Bioelectronics
JF - Biosensors and Bioelectronics
M1 - 116822
ER -