摘要
The substantial inertia of the boiler restricts the flexibility of circulating fluidized bed (CFB) power units. To enhance the load ramp-up capability of the CFB power unit, we proposed a novel control strategy considering the spatial-temporal evolution of its internal stored energy. A dynamic model of the subcritical CFB power unit with a capacity of 300 MW was developed, incorporating the mechanism and control modules. By analyzing the spatial-temporal evolution of the stored energy in bed material, flue gases, refractory materials, economizer, evaporation subsystem, superheater subsystem, reheater subsystem, and turbine subsystem, we identified that the over-utilization of chemical and thermal stored energy in the bed materials is the primary factor restricting load ramp-up, while the thermal stored energy of the economizer is suitable for further utilization. Under the optimized control strategy that utilizes deviations of stored energy per mass of bed materials as a feedforward mechanism, the deviations of the key operating parameters during the load ramp-up process are significantly reduced, and the load ramp-up rate of the subcritical CFB power unit can be improved from 2.0 % Pe/min to 3.0 % Pe/min.
| 源语言 | 英语 |
|---|---|
| 期刊论文编号 | 132571 |
| 期刊 | Energy |
| 卷 | 307 |
| DOI | |
| 出版状态 | 已出版 - 30 10月 2024 |
联合国可持续发展目标
此成果有助于实现下列可持续发展目标:
-
可持续发展目标 7 经济适用的清洁能源
学术指纹
探究 'Enhancing the load ramp-up capability of the subcritical CFB power unit by considering the evolution of internal stored energy' 的科研主题。它们共同构成独一无二的学术指纹。引用此