跳到主要导航 跳到搜索 跳到主要内容

Enhancing the load ramp-up capability of the subcritical CFB power unit by considering the evolution of internal stored energy

  • Chenyu Zhao
  • , Chaoyang Wang
  • , Jianlin Fan
  • , Ming Liu
  • , Jiping Liu
  • , Junjie Yan
  • Xi'an Jiaotong University
  • Ltd

科研成果: 期刊稿件文章同行评审

14 引用 (Scopus)

摘要

The substantial inertia of the boiler restricts the flexibility of circulating fluidized bed (CFB) power units. To enhance the load ramp-up capability of the CFB power unit, we proposed a novel control strategy considering the spatial-temporal evolution of its internal stored energy. A dynamic model of the subcritical CFB power unit with a capacity of 300 MW was developed, incorporating the mechanism and control modules. By analyzing the spatial-temporal evolution of the stored energy in bed material, flue gases, refractory materials, economizer, evaporation subsystem, superheater subsystem, reheater subsystem, and turbine subsystem, we identified that the over-utilization of chemical and thermal stored energy in the bed materials is the primary factor restricting load ramp-up, while the thermal stored energy of the economizer is suitable for further utilization. Under the optimized control strategy that utilizes deviations of stored energy per mass of bed materials as a feedforward mechanism, the deviations of the key operating parameters during the load ramp-up process are significantly reduced, and the load ramp-up rate of the subcritical CFB power unit can be improved from 2.0 % Pe/min to 3.0 % Pe/min.

源语言英语
期刊论文编号132571
期刊Energy
307
DOI
出版状态已出版 - 30 10月 2024

联合国可持续发展目标

此成果有助于实现下列可持续发展目标:

  1. 可持续发展目标 7 - 经济适用的清洁能源
    可持续发展目标 7 经济适用的清洁能源

学术指纹

探究 'Enhancing the load ramp-up capability of the subcritical CFB power unit by considering the evolution of internal stored energy' 的科研主题。它们共同构成独一无二的学术指纹。

引用此