TY - JOUR
T1 - Enhanced Performance of 200-kHz PMN-PT Crystal Transducers Through Medium-Temperature AC Poling and Electrically Parallel Stacking
AU - Jiang, Zibo
AU - Wu, Kaijia
AU - Ye, Zuo Guang
N1 - Publisher Copyright:
© 1986-2012 IEEE.
PY - 2025
Y1 - 2025
N2 - Despite their excellent piezoelectric properties, relaxor-based ferroelectric crystals have not been widely used in medium- to low-frequency ultrasound transducers because of the low sensitivity arising from a low capacitance and the low signal intensity due to a weak coercive field of the piezoelectric materials. In this study, a new type of transducer has been designed and fabricated by stacking two PMN-0.27PT crystals of opposite polarizations poled under optimized poling conditions, which exhibits an enhanced element capacitance and improved piezoelectric performance, leading to a better sensitivity and a broader bandwidth. It is found that using the optimized condition of low-voltage alternative current poling (ACP) (square wave 205 Vrms/mm, three cycles at 0.1 Hz) at a medium temperature of 65~^{\circ } C [medium-temperature low-voltage ACP MT-LV ACP)], the relative permittivity of the crystal is increased by 16%, the electromechancial coupling factor increased by 6%, and the piezoelectric coefficient increased by 27%, compared with the conventional direct current poling at room temperature (RT DCP). The 200-kHz single-element transducer fabricated from the MT-LV ACP single-layer PMN-0.27PT crystal exhibits a −6-dB bandwidth that is increased by 6.4% and a receiver free field voltage response that is increased by 23.6%, respectively, compared with a similar transducer made from RT DCP single-layer PMN-0.27PT. In addition, the transducer fabricated from two stacked PMN-0.27PT platelets of identical thicknesses but opposite poling directions not only produce similar center frequency and bandwidth as the transducer made from single layer crystal of the same height but also produce quadrupled element capacitance, which leads to a much better electrical impedance match, resulting in a sensitivity increase up to 224%.
AB - Despite their excellent piezoelectric properties, relaxor-based ferroelectric crystals have not been widely used in medium- to low-frequency ultrasound transducers because of the low sensitivity arising from a low capacitance and the low signal intensity due to a weak coercive field of the piezoelectric materials. In this study, a new type of transducer has been designed and fabricated by stacking two PMN-0.27PT crystals of opposite polarizations poled under optimized poling conditions, which exhibits an enhanced element capacitance and improved piezoelectric performance, leading to a better sensitivity and a broader bandwidth. It is found that using the optimized condition of low-voltage alternative current poling (ACP) (square wave 205 Vrms/mm, three cycles at 0.1 Hz) at a medium temperature of 65~^{\circ } C [medium-temperature low-voltage ACP MT-LV ACP)], the relative permittivity of the crystal is increased by 16%, the electromechancial coupling factor increased by 6%, and the piezoelectric coefficient increased by 27%, compared with the conventional direct current poling at room temperature (RT DCP). The 200-kHz single-element transducer fabricated from the MT-LV ACP single-layer PMN-0.27PT crystal exhibits a −6-dB bandwidth that is increased by 6.4% and a receiver free field voltage response that is increased by 23.6%, respectively, compared with a similar transducer made from RT DCP single-layer PMN-0.27PT. In addition, the transducer fabricated from two stacked PMN-0.27PT platelets of identical thicknesses but opposite poling directions not only produce similar center frequency and bandwidth as the transducer made from single layer crystal of the same height but also produce quadrupled element capacitance, which leads to a much better electrical impedance match, resulting in a sensitivity increase up to 224%.
KW - AC poling
KW - PMN-PT single crystals
KW - crystal stacking
KW - electrical impedance match
KW - medium-temperature poling
KW - ultrasound transducer
UR - https://www.scopus.com/pages/publications/105005460765
U2 - 10.1109/TUFFC.2025.3570735
DO - 10.1109/TUFFC.2025.3570735
M3 - 文章
C2 - 40378034
AN - SCOPUS:105005460765
SN - 0885-3010
VL - 72
SP - 979
EP - 986
JO - IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
JF - IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
IS - 7
ER -