摘要
The photomultiplier tube (PMT) responding to direct neutron irradiation has an extreme effect on the scintillation detector design and its practical applications. The response mechanism of a photomultiplier tube interacting with an accelerator neutron source was investigated. 10B(n, α), 28Si(n, α) and 28Si(n, p) reactions in borosilicate glass of the end window lead to fluorescence yield, and then the fluorescence was converted into electrons by the photocathode. Experiments were carried out with EMI photomultiplier tubes (9815B and 9850B) at 5SDH-2 accelerator and the responses to neutrons with neutron energy ranging between 0.5 MeV and 5 MeV were obtained. The results show that the spectral sensitivities increase with the incident neutron energy. The sensitivity ratio of 9815B to 9850B is about 102, which is in good agreement with the gain ratio between 9815B and 9850B.
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 1427-1430 |
| 页数 | 4 |
| 期刊 | Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams |
| 卷 | 17 |
| 期 | 9 |
| 出版状态 | 已出版 - 9月 2005 |
| 已对外发布 | 是 |
学术指纹
探究 'Energy response of photomultiplier tubes to neutron irradiation' 的科研主题。它们共同构成独一无二的学术指纹。引用此
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver