摘要
The cold-pressing welding method is employed to fabricate persistent joints between NbTi multifilamentary conductors, and a series of persistent joints are thus made at different mechanical pressures. The electrical properties of these persistent joints are tested by a joint resistance measurement device based on the current decay measurement method. Test results show that the cold-pressing welding method is reliable and applicable to NMR and MRI applications. Experiment results also shows that the joint resistances and current-carrying capacities of the joints seem to have no apparent relevance to the mechanical pressure in a wide range of 4-20 MPa, but the current decay ratio due to flux creep has obvious relevance to the mechanical pressure. Further research is needed to advance this joint manufacturing technology. Besides, measured current increase under 1 T background magnetic field is observed and explained, which has a reference meaning for testing persistent joint resistances.
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 62-67 |
| 页数 | 6 |
| 期刊 | Cryogenics |
| 卷 | 58 |
| DOI | |
| 出版状态 | 已出版 - 12月 2013 |
学术指纹
探究 'Electrical properties of cold-pressing welded NbTi persistent joints' 的科研主题。它们共同构成独一无二的指纹。引用此
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver