Many defects of single crystals are caused by the nonplanar solidification front. The transverse temperature gradient at melt–crystal interface results in nonplanar solidification fronts. The location of a cast in the directional solidification furnace affects heat dissipation and thus influences the transverse temperature gradient. This paper presents a criterion and a searching algorithm to find the optimal location of the cast for flattening the solidification front. A numerical simulation was employed for the verification of our method. Additionally, the effects of the size of the cooling device of the furnace on the optimal location, the transverse temperature gradient and the solidification time were discussed. The transverse temperature gradient is reduced about 50% without increasing much solidification time when setting the cast with a varying thickness mould at the optimal location. In addition, the optimal location is mainly influenced by the radius of the cooling ring.

源语言英语
页(从-至)33-41
页数9
期刊Journal of Crystal Growth
卷451
DOI
出版状态已出版 - 1 10月 2016